Daikin RXYQ-TA Series Service Manual page 145

Heat pump 60 hz
Table of Contents

Advertisement

SiUS341615E
Error code
E9
-
-
-
-
-
-
-
-
-
10
-
20
-
21
-
22
-
23
-
24
-
25
F3
-
-
-
-
20
-
21
-
22
F4
-
-
-
-
-
-
-
-
-
-
10
-
11
-
12
-
13
-
14
F6
-
H3
-
-
-
-
-
-
Field Settings
1
Electronic expansion valve 2 coil (Y2E) error – Master unit
3
Electronic expansion valve 3 coil (Y3E) error – Master unit
4
Electronic expansion valve 1 coil (Y1E) error – Master unit
5
Electronic expansion valve 2 coil (Y2E) error – Slave unit 1
6
Electronic expansion valve 3 coil (Y3E) error – Slave unit 1
7
Electronic expansion valve 1 coil (Y1E) error – Slave unit 1
8
Electronic expansion valve 2 coil (Y2E) error – Slave unit 2
9
Electronic expansion valve 3 coil (Y3E) error – Slave unit 2
Electronic expansion valve 1 coil (Y1E) error – Slave unit 2
Defective electronic expansion valve 1 coil (Y1E) – Master unit
Defective electronic expansion valve 1 coil (Y1E) – Slave unit 1
Defective electronic expansion valve 1 coil (Y1E) – Slave unit 2
Defective electronic expansion valve 2 coil (Y2E) – Master unit
Defective electronic expansion valve 2 coil (Y2E) – Slave unit 1
Defective electronic expansion valve 2 coil (Y2E) – Slave unit 2
1
Discharge pipe high temperature error – Master unit
3
Discharge pipe high temperature error – Slave unit 1
5
Discharge pipe high temperature error – Slave unit 2
Compressor overheat error – Master unit
Compressor overheat error – Slave unit 1
Compressor overheat error – Slave unit 2
1
Wet alarm
2
Wet alarm for inverter compressor 1 – Master unit
3
Wet alarm for inverter compressor 2 – Master unit
4
Wet alarm for inverter compressor 1 – Slave unit 1
5
Wet alarm for inverter compressor 2 – Slave unit 1
6
Wet alarm for inverter compressor 1 – Slave unit 2
7
Wet alarm for inverter compressor 2 – Slave unit 2
8
Wet error for inverter compressor 1 – Master unit
9
Wet error for inverter compressor 2 – Master unit
Wet error for inverter compressor 1 – Slave unit 1
Wet error for inverter compressor 2 – Slave unit 1
Wet error for inverter compressor 1 – Slave unit 2
Wet error for inverter compressor 2 – Slave unit 2
Indoor unit failure alarm
2
Refrigerant overcharged
2
Connection error (Control & inverter PCB 1 (A3P)) – Master unit
3
Connection error (Control & inverter PCB 2 (A6P)) – Master unit
4
Connection error (Control & inverter PCB 1 (A3P)) – Slave unit 1
5
Connection error (Control & inverter PCB 2 (A6P)) – Slave unit 1
6
Connection error (Control & inverter PCB 1 (A3P)) – Slave unit 2
7
Connection error (Control & inverter PCB 2 (A6P)) – Slave unit 2
Description of error
Field Settings for Outdoor Unit
Upper code
Lower code
SEG
SEG
SEG
SEG
SEG
1
2
3
1
2
E
9
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
1
-
2
-
2
-
2
-
2
-
2
-
2
F
3
-
1
-
1
-
1
-
2
-
2
-
2
F
4
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
1
-
1
-
1
-
1
-
1
F
6
-
0
H
3
-
0
-
0
-
0
-
0
-
0
-
0
SEG
3
1
3
4
5
6
7
8
9
0
0
1
2
3
4
5
1
3
5
0
1
2
1
2
3
4
5
6
7
8
9
0
1
2
3
4
2
2
3
4
5
6
7
132