Daikin RXYQ-TA Series Service Manual page 144

Heat pump 60 hz
Table of Contents

Advertisement

Field Settings for Outdoor Unit
Error code
-
E1
-
-
E2
-
-
-
-
-
-
E3
-
-
-
-
-
-
13
-
14
-
15
-
18
-
E4
-
-
-
E5
-
-
-
-
-
E7
-
-
-
-
-
-
10
-
13
-
14
-
17
-
18
-
21
-
22
-
25
-
26
-
29
-
30
-
33
-
34
131
1
Outdoor unit PCB error
2
Defective outdoor unit PCB
1
Ground leakage detection error – Master unit
2
Ground leakage detection error – Slave unit 1
3
Ground leakage detection error – Slave unit 2
6
Missing of ground leakage detection core – Master unit
7
Missing of ground leakage detection core – Slave unit 1
8
Missing of ground leakage detection core – Slave unit 2
1
Actuation of high pressure switch – Master unit
2
High pressure - refrigerant overcharge or closed stop valve – Master unit
3
Actuation of high pressure switch – Slave unit 1
4
High pressure - refrigerant overcharge or closed stop valve – Slave unit 1
5
Actuation of high pressure switch – Slave unit 2
6
High pressure - refrigerant overcharge or closed stop valve – Slave unit 2
Liquid stop valve check error – Master unit
Liquid stop valve check error – Slave unit 1
Liquid stop valve check error – Slave unit 2
Overall retry of high pressure switch
1
Low pressure sensor error – Master unit
2
Low pressure sensor error – Slave unit 1
3
Low pressure sensor error – Slave unit 2
1
Inverter compressor 1 lock – Master unit
2
Inverter compressor 1 lock – Slave unit 1
3
Inverter compressor 1 lock – Slave unit 2
7
Inverter compressor 2 lock – Master unit
8
Inverter compressor 2 lock – Slave unit 1
9
Inverter compressor 2 lock – Slave unit 2
1
Fan motor 1 lock – Master unit
2
Fan motor 2 lock – Master unit
5
Fan motor 1 momentary overcurrent – Master unit
6
Fan motor 2 momentary overcurrent – Master unit
9
Fan motor 1 IPM error – Master unit
Fan motor 2 IPM error – Master unit
Fan motor 1 lock – Slave unit 1
Fan motor 2 lock – Slave unit 1
Fan motor 1 momentary overcurrent – Slave unit 1
Fan motor 2 momentary overcurrent – Slave unit 1
Fan motor 1 IPM error – Slave unit 1
Fan motor 2 IPM error – Slave unit 1
Fan motor 1 lock – Slave unit 2
Fan motor 1 lock – Slave unit 2
Fan motor 1 momentary overcurrent – Slave unit 2
Fan motor 2 momentary overcurrent – Slave unit 2
Fan motor 1 IPM error – Slave unit 2
Fan motor 2 IPM error – Slave unit 2
Description of error
SiUS341615E
Upper code
Lower code
SEG
SEG
SEG
SEG
SEG
1
2
3
1
2
E
1
-
0
-
0
E
2
-
0
-
0
-
0
-
0
-
0
-
0
E
3
-
0
-
0
-
0
-
0
-
0
-
0
-
1
-
1
-
1
-
1
E
4
-
0
-
0
-
0
E
5
-
0
-
0
-
0
-
0
-
0
-
0
E
7
-
0
-
0
-
0
-
0
-
0
-
0
-
1
-
1
-
1
-
1
-
2
-
2
-
2
-
2
-
2
-
3
-
3
-
3
Field Settings
SEG
3
1
2
1
2
3
6
7
8
1
2
3
4
5
6
3
4
5
8
1
2
3
1
2
3
7
8
9
1
2
5
6
9
9
3
4
7
8
1
2
5
6
9
0
3
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents