Dimensions EDMY041425 4. Dimensions Indoor Unit FTXZ25/35/50NVMM THE MARK (→) SHOWS PIPING DIRECTION REQUIRED SPACE AIR FLOW (INDOOR) DISTANCE FROM WALL DISTANCE FROM WALL MIN.50 FOR OPERATION MIN.50 FOR OPERATION LEFT GRILLE FIXED SCREWS (RECOMMENDED) OPERATION LAMP QUICK HEATING (RECOMMENDED) (INSIDE PANEL) MIN.20 FOR INSTALLATION INTELLIGENT EYE...
EDMY041425 Wiring Diagrams 5. Wiring Diagrams Indoor Unit FTXZ25/35/50NVMM CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK FIELD WIRING. ON AGAIN. outdoor A1P~A4P A6P, A7P : PRINTED CIRCUIT BOARD C104, C105 : CAPACITOR : FLAME GROUND : FUSE...
Piping Diagrams EDMY041425 6. Piping Diagrams Indoor Unit FTXZ25/35/50NVMM INDOOR UNIT HEAT EXCHANGER HEAT EXCH. THERMISTOR CROSS FLOW FAN (DC) FAN MOTOR FIELD PIPING (6.4CuT) SINGLE UNION JOINT 9.5CuT FIELD PIPING (9.5CuT) SINGLE UNION JOINT ROOM TEMPERATURE SENSOR HUMIDITY SENSOR (INDOOR) REFRIGERANT FLOW COOLING...
Operation Limit EDMY041425 8. Operation Limit RXZ25/35/50NVM Heating Cooling (-20˚CDB) Indoor temp. (˚CDB) Notes: Indoor temp. (˚CWB) The graphs are based on the following conditions. • Equivalent piping length 7.5m • Level difference 3D087020 • Air flow rate High Split Type Air Conditioners FTXZ-N Series...
EDMY041425 Sound Level 9. Sound Level Measuring Location Indoor Unit Outdoor Unit MICROPHONE MICROPHONE Notes: 1. Operation sound is measured in an anechoic chamber. 2. The data are based on the conditions shown in the table below. Cooling Heating Piping Length Indoor ;...
Electric Characteristics EDMY041425 10. Electric Characteristics Power Supply Indoor Unit Outdoor Unit Hz - Volts Voltage Range 50 - 220 MAX. 50 Hz, 264 V 50 - 230 MIN. 50 Hz, 198 V FTXZ25NVMM RXZ25NVM 50 - 240 10.5 60 - 220 MAX.
EDMY041425 Optional Accessories 13. Optional Accessories 13.1 Option List 13.1.1 Indoor Unit Option Name Model Name Centralised control board-up to 5 rooms ★ 1 KRC72A Wiring adaptor for timer clock / remote controller ★ 2 KRP413AB1S (normal open pulse contact / normal open contact) Central remote controller ★...
Optional Accessories EDMY041425 13.3 <KRP928BB2S> Interface Adaptor for DIII-NET (Residential Air Conditioner) Split Type Air Conditioners FTXZ-N Series...
Page 85
EDMY041425 Optional Accessories C: 3P248024-1D Split Type Air Conditioners FTXZ-N Series...
Page 86
Optional Accessories EDMY041425 Connection to Remote Control PC-board 3P248024-3D Split Type Air Conditioners FTXZ-N Series...
EDMY041425 Optional Accessories 13.4 <KPW937D4> Air Direction Adjustment Grille Component parts Be sure to check that the following parts are included before installation. Air direction Installation M4 x 30 Screw Name Seal Spacer adjustment grille manual Shape Qty. 1 pc . 4 pcs.
Page 88
Optional Accessories EDMY041425 <Square outlet grille whose thickness is 20mm> Remove the outlet grille. Attach the seal ( ) to the front panel 1.Remove the 4 outlet grille fixing screws. 2.After lifting the outlet grille, move it forward to remove it from the front panel. Front panel Outlet grille fixing screw...
Page 92
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.