4. How to program the adjustable frequency
drive
[1634] Heatsink Temp.
[1635] Thermal Drive Load
[1636] Inv. Nom. Current
[1637] Inv. Max. Current
[1638] SL Control State
4
[1639] Control Card Temp.
[1650] External Reference
[1652] Feedback [Unit]
[1653] DigiPot Reference
[1654] Feedback 1 [Unit]
[1655] Feedback 2 [Unit]
[1656] Feedback 3 [Unit]
[1660] Digital Input
[1661] Terminal 53 Switch
[1662] Analog Input 53
[1663] Terminal 54 Switch
[1664] Analog Input 54
[1665] Analog
[1666] Digital Output [bin]
[1667] Freq. Input #29 [Hz] Actual value of the frequency applied at terminal 29 as a pulse
[1668] Freq. Input #33 [Hz] Actual value of the frequency applied at terminal 33 as a pulse
[1669] Pulse
[1670] Pulse
[1671] Relay Output [bin]
80
Present heatsink temperature of the adjustable frequency drive.
The cut-out limit is 203° F ± 9° F [95° C ± 5° C]; cutting back
in occurs at 158° F ± 9° F [70° C ± 5° C].
Percentage load of the inverters
Nominal current of the adjustable frequency drive.
Maximum current of the adjustable frequency drive.
State of the event executed by the control.
Temperature of the control card.
Sum of the external reference as a percentage, i.e., the sum of
analog/pulse/bus.
Signal value in units from the programmed digital input(s).
View the contribution of the digital potentiometer to the actual
reference feedback.
View the value of Feedback 1. See also par. 20-0*.
View the value of Feedback 2. See also par. 20-0*.
View the value of Feedback 3. See also par. 20-0*.
Displays the status of the 6 digital input terminals (18, 19, 27,
29, 32 and 33). Input 18 corresponds to the bit at the far left.
Signal low = 0; Signal high = 1
Setting of input terminal 53. Current = 0; Voltage = 1.
Setting
Actual value at input 53 either as a reference or protection val-
ue.
Setting of input terminal 54. Current = 0; Voltage = 1.
Setting
Actual value at input 54 either as reference or protection value.
Output
42
Actual value at output 42 in mA. Use par. 6-50 to select the
[mA]
variable to be represented by output 42.
Binary value of all digital outputs.
input.
input.
Output
#27
Actual value of pulses applied to terminal 27 in digital output
[Hz]
mode.
Output
#29
Actual value of pulses applied to terminal 29 in digital output
[Hz]
mode.
View the setting of all relays.
MG.20.P1.22 - VLT
VLT AQUA High Power Instruction Manual
®
is a registered Danfoss trademark.