Surroundings:
Enclosure ≤ enclosure type D
Enclosure ≥ enclosure type D, E
Enclosure kit available ≤ enclosure type D
Vibration test
Max. relative humidity
Aggressive environment (IEC 721-3-3), uncoated
Aggressive environment (IEC 721-3-3), coated
Test method according to IEC 60068-2-43 H2S (10 days)
Ambient temperature
Ambient temperature
Derating for high ambient temperature, see the Design Guide, section on Special Conditions
Minimum ambient temperature during full-scale operation
Minimum ambient temperature at reduced performance
Temperature during storage/transport
Maximum altitude above sea level without derating
Maximum altitude above sea level with derating
Derating for high altitude, see section on special conditions.
EMC standards, Emission
EMC standards, Immunity
See section on special conditions.
Control card performance:
Scan interval
Control card, USB serial communication:
USB standard
USB plug
5%-95% (IEC 721-3-3; Class 3K3 (non-condensing) during operation
Max. 113° F [45° C] (AVM switching mode only!) and max. 104° F [40°
Max. 104° F [40° C] (SFAVM switching mode only!) and max. 95° F [35°
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN
Connection to PC is carried out via a standard host/device USB cable.
The USB connection is galvanically isolated from the supply voltage (PELV) and other
high-voltage terminals.
The USB connection is not galvanically isolated from protection ground. Use only
isolated laptop/PC as connection to the USB connector on VLT AQUA Drive or an
isolated USB cable/drive.
®
MG.20.P1.22 - VLT
is a registered Danfoss trademark.
-13°-+149°/158° F [-25°-+65°/70° C]
EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
EN 61800-3, EN 61000-6-1/2,
5. General Specifications
IP 00, IP 21, IP 54
IP 21, IP 54
IP 21/TYPE 1/IP 4X top
1.0 g
class 3C2
class 3C3
C] over a 24 hour period.
C] over a 24 hour period.
32° F [0° C]
14° F [-10° C]
3280 ft [1000 m]
9842 ft [3000 m]
61000-4-6
: 5 ms
1.1 (Full speed)
USB type B "device" plug
5
139