Error Numbers - Festo MSE6-E2M Mounting, Installation, Commissioning

Energy efficiency module
Hide thumbs Also See for MSE6-E2M:
Table of Contents

Advertisement

8
Diagnostics and error handling
8.4

Error numbers

Possible errors of the MSE6-E2M are divided into three error classes with different priority, depending
on the seriousness of the error. If an error occurs, the system error LED (SF LED) will flash depending on
the error class.
SF (System Failure) – system fault
LED (red)
Sequence
ON
OFF
LED not illuminated
ON
OFF
LED flashes
ON
OFF
LED flashes
ON
OFF
LED flashes
1) The system error LED flashes, depending on the error class.
Error class 1 (simple error): 1 * flash, pause
Error class 2 (error)
Error class 3 (serious error): 3 * flash, pause
Tab. 8.2 LED SF
If several errors occur together, the error with the highest priority will have precedence. This means
that:
– The system error LED flashes according to the higher priority
– The number of the error with the higher priority will be entered in the system diagnostic data under
function number 1938 (error number).
Within an error class, errors of modules with a lower module number have higher priority. For example,
errors of module number 0 have the highest priority within an error class. Errors of module number 1
have the second highest priority, etc.
Festo – MSE6-E2M-IN-EN – 2017-07c – English
1)
2 * flash, pause
Status
No error
Simple error/information
(error class 1)
Error
(error class 2)
Serious error
(error class 3)
Significance/
error handling
An overview of
all error num­
bers can be
found in the de­
scription for the
CPX terminal
(è Tab. 1)
35

Advertisement

Table of Contents
loading

Table of Contents