Diagnostics
10.1

Error numbers

Error
Error
Meaning
no.
chan-
nel
1)
0
No error or end of a message status [No error]
2
Short circuit/overload [Short circuit]
Em.3
Short circuit/
Overload sensor
supply
24V DC Usen
2
Am.0
Short circuit/
overload at elec-
trical outputs on
at least one
electrical output
74
Remedy
Eliminate short circuit/overload and
check connected sensors if necessary.
Depending on the set parameter value,
behaviour according to SCS (Pm.27.6):
Setting 1 = switch on again: sensor
supply voltage is automatically
switched on again after elimination
of short-circuit/overload
Setting 0 = leave off. Switching on
the sensor supply voltage again:
Power Off/On necessary.
or
Change parameter "Behaviour after
SCS" (Pm.27.6) to 1 = switch on
again
Check the connected actuators, elimin-
ate short circuit/overload if necessary.
The number of the faulty channel is sig-
nalled in the inputs Em.3.14 (DO0) and
Em.3.15 (DO1).
Activation para-
meter
cannot
Can be deactiv-
ated
Pm.0.0
Monitoring
Short circuit/
Overload
Sensor supply
Pm.0.1
Monitoring
Short circuit/
Overload
Electrical out-
puts
Festo — MSE6-C2M — 2019-03