Festo MSE6-E2M Mounting, Installation, Commissioning page 39

Energy efficiency module
Hide thumbs Also See for MSE6-E2M:
Table of Contents

Advertisement

A
Technical appendix
Vibration load
Frequency range [Hz]
SL1
SL2
2...8
2...8
8...41
8...27
41...58
27...60
58...160
60...160
160...200
160...200
Shock load
Acceleration [m/s²]
SL1
SL2
±150
±300
Continuous shock load
Acceleration [m/s²]
±150
Tab. A.2 Values for vibration and shock in accordance with IEC 60068
Festo – MSE6-E2M-IN-EN – 2017-07c – English
Acceleration [m/s²]
SL1
SL2
10
10
20
50
10
10
Duration [ms]
SL1
SL2
11
11
Duration [ms]
6
Deflection [mm]
SL1
SL2
±3.5
±3.5
±0.15
±0.35
Shocks per direction
SL1
SL2
5
5
Shocks per direction
1000
39