A
Technical appendix
A
Technical appendix
A.1

Technical data

MSE6
Operating pressure
Operating pressure,
Overload range
1)
Operating medium
Note on the operating medium
Temperature of medium
Mounting position
Standard nominal flow rate
1 } 2
In main flow direction
Standard nominal flow rate
2 } 1
In relief direction
Product weight
Operating voltage supply
Electronics/sensor
– Nominal voltage
– Current consumption at 24 V [mA]
Actuator technology load
voltage supply
– Nominal voltage
– Current consumption
– Undervoltage diagnostic
message (trigger level
without hysteresis)
5)
Pressure sensor
– Pressure measuring range
– Accuracy
– Repetition accuracy
Festo – MSE6-E2M-IN-EN – 2017-07c – English
-E2M
[bar]
4 ... 10
[MPa]
0.4 ... 1
[bar]
10 ... 12
[MPa]
1 ... 1.2
Compressed air to ISO 8573­-1:2010 [7:4:4]
Nitrogen
Lubricated operation not possible
[°C]
0 ... 50
Horizontal ±5°
2)
[l/min.]
4500
2)
[l/min.]
4500
[g]
Max. 3500
[V DC]
24 ±25 %
Max. 300
[V DC]
24 –25 %/+10 %
[mA]
Typ. 100 E2M-function module
+ typ. 70 if shut-off valve in the blocking state
+ typ. intrinsic current consumption of the corresponding
bus node (è Tab. 1)
[V]
15 ... 17
[bar]
0 ... 14
[MPa]
0 ... 1.4
[%FS]
typ. ±3
[%FS]
±0.3
3)
37