Warning
Risk of injury
Stopping the controller (e.g. after the transmission of parameters, system configuration
or control program) interrupts the communication to the
valve then switches to the initial position (pressurise). If the valve was previously
closed, the system is pressurised. If the system was vented, pressurisation takes place
suddenly.
• Use appropriate measures to ensure that unintentional pressurisation of the system
is not possible.
Warning
Risk of injury
If the load or operating voltage of the MSE6-E2M is switched off, then the shut-off valve
switches to the initial position (pressurise). If the valve was previously closed, the sys­
tem is pressurised. If the system was vented, pressurisation takes place suddenly.
• Use appropriate measures to ensure that unintentional pressurisation of the system
is not possible.
The MSE6-E2M is equipped with a pneumatically-piloted shut-off valve. With preset parameters and
applied input pressure P1, the valve automatically switches to the "pressurise" status in the following
cases:
– Switch-off of the operating voltage or the load voltage
– Interruption of the network communication with correspondingly set system parameters
– Stopping of the higher-order controller (see manufacturer's specifications), e.g. in the case of trans­
mission of control programs, parameters, configuration data.
Festo – MSE6-E2M-IN-EN – 2017-07c – English
MSE6-E2M,
and the shut-off
25