ILX Lightwave LDX-36000 Series User Manual page 30

High power laser diode current source
Table of Contents

Advertisement

1
C H A P T E R
Table 1.2
LDX-36000 Series Specifications
INTERLOCKS
Interlock 1
Interlock 2
22
Fault Response Time
GENERAL
GPIB Interface
On-Board Memory Storage
On-Board Upload Rate
Power Requirements
Maximum Current Draw
23
Size (H x W x D)
Weight
Operating Temperature
Storage Temperature
Safety
EMC
Regulatory Compliance
CE
Connectors
Current Output
Measurement
Interlocks
Pulse Trigger Out
Input/Output Trigger
1.
All values measured after 1-hour warm-up and at 25°C.
2.
± (% of setpoint + mA).
3.
Time from 50% of current ramp to set point for step sizes 3A or less.
4.
From the rising edge of the pulse to the set point.
5.
At the end of CC-390 output cable in CW mode; 10% de-rating in QCW mode.
6.
% of full scale over 1 hour, all instrument modes
7.
RMS electrical noise measured on a resistive load over a 300 KHz bandwidth.
8.
Maximum output current transient from normal operations (e.g. power on-off, current on-off), as well as accidental situations (e.g. power line plug removal).
Normal operations exclude pulse characteristics such as overshoot and undershoot.
9.
Maximum output current transient from a 1000 V power line transient spike.
10.
All QCW mode pulse specifications taken with ILX CC-390 output cable. Use of the instrument with alternative cabling may affect pulse performance.
11.
% of reading
12.
Measured from 10% to 90% points at half-scale output at the end of an ILX CC-390 cable into a non-inductive load.
14
LDX-36000 Series
I N T R O D U C T I O N A N D S P E C I F I C A T I O N S
Specifications
36010-35
Adjustable current and voltage limit; redundant hardware current and voltage limit
Error monitoring and reporting
Normally open, close to enable output
Normally open, close to enable output
<6 ms
IEEE/488
1000 points
30 ms/point
100/240 VAC +
10%
7A/3.5A
146mm x 483mm x 451mm (5.25" x 19" x 17.75")
11.3 kg/25 lbs
o
o
0
C to 40
C
o
o
-40
C to 70
C
EN60950 Low Voltage Directive
21CFR 1040.10
CE Certified
EN61326-1: 2006 Basic Requirements; Immunity
EN55011:1007 Radiated and Conducted Emissions
EN61010-1: Safety Requirements
Hybrid D-sub
DB 9 rear panel
Terminal block
BNC rear panel
BNC front panel
(Continued) (Sheet 8 of 8)
36018-35
36040-30
100/240 VAC +
100/240 VAC +
10%
10%
12A/6A
20A/10A
11.9 kg/26 lbs
13.6 kg/30 lbs
Hybrid D-sub
Hybrid D-sub
36070-30
36125-24
220/240 VAC +
220/240 VAC +
10%
10%
13A
16A
16.3 kg/36 lbs
18.9 kg/41 lbs
Bus Bar
Bus Bar

Hide quick links: