Returns the value of the Status Event Register.
None.
The response is the sum of the enabled bits and must be a value between 0 and 65535
as detailed below.
1
Laser Current Limit
2
Laser Voltage Limit
4
High Temperature Limit
8
Laser Open Circuit
16
Interlock 1 State Change
32
Interlock 2 State Change
64
Temp Sensor Open
128
Temp Sensor Shorted
The enabled or disabled events can be set via the LASer:ENABle:EVEnt command.
The event status is only cleared when the event status is read or by the *CLS command,
while the condition status (LAS:COND?) is constantly changing.
"LAS:EVE?" -response: "257" means, that the output status has changed and current
limit events have occurred since the last LASer:EVEnt? query.
C
OMMON
F
RONT
D
EVICE
256
Output On
512
Bad Steinhart-Hart Conversion
1024
Hardware Current Limit
2048
AC Power Failure
4096
Laser Open Circuit 2
8192
Power Supply Failure
16384
Power Supply Voltage Limit
32768
Pass Element Power Limit