Ambient Conditions And Installation Location; Installation Example - YASKAWA MPL300-J00 Operating And Maintenance Manual

Table of Contents

Advertisement

Installation
4.2
When installing a robot, it is necessary to satisfy the undermentioned environmental
conditions:
Ambient temperature: From 0°C to +45°C.
Air humidity: 20% to 80% relative humidity (non-condensing).
Free of corrosive gases, liquids, or explosive gases. No water, oil or dust and free from
excessive electrical noise (plasma).
Free from excessive vibration (Vibration acceleration: 4.9 m/s² [0.5 G] or less).
Maximum unevenness of the support surface of the robot base: 0.5 mm.
4.3
1. At the first set out, anchor the base plate firmly onto the floor.
2. The robot base is tapped for 8 mounting holes. Fix the robot base with the screws M20
(Strength category 12.9) Minimum length: 80 mm.
3. Next, fix the robot base to the base plate. Tighten the hexagon head bolts and anchor
bolts securely so that they will not work loose during operation (see figure „Mounting of
the robot on the base plate").
8 Screws M20
1
Spring washer
2
Washer
3
Robot base
4
Base plate
5
at least 40 mm
6
-
4
18

Ambient conditions and installation location

Installation example

Fig. 4-1: Mounting the robot on the base plate
7
Anchor bolt (M24 or greater)
H7
2 holes Ø 20
8
8 holes Ø22
9
H7
Hole Ø 12
10
adhesive
11