Emulating An Edid To All Input Ports; Copy An Edid To User Memory; Deleting An Edid From User Memory; Resetting The Emulated Edids - Lightware HDMI-3D-OPT-TX210A User Manual

Fiber optical multimedia extender
Hide thumbs Also See for HDMI-3D-OPT-TX210A:
Table of Contents

Advertisement

 
7. LW3 Programmer's Reference
7.12.5. Emulating an EDID to All Input Ports
Command format:
CALL●/EDID:switchAll(<source>)
Response format:
mO●/EDID:switchAll
Example:
˃ CALL /EDID:switchAll(F47)
˂ mO /EDID:switchAll
Legend:
<source>
Source EDID memory place: Factory / User / Dynamic.
7.12.6. Copy an EDID to User Memory
Command format:
CALL●/EDID:copy(<D
Response format:
mO●/EDID:copy
Example:
˃ CALL /EDID:copy(D1:U1)
˂ mO /EDID:copy
Explanation: The EDID of the last connected sink of D1 (Output 1) has been copied to U1.
7.12.7. Deleting an EDID from User Memory
Command format:
CALL●/EDID:delete(<U
Response format:
mO●/EDID:delete
Example:
˃ CALL /EDID:delete(U1)
˂ mO /EDID:delete
7.12.8. Resetting the Emulated EDIDs
Command format:
CALL●/EDID:reset()
Response format:
mO●/EDID:reset
Example:
˃ CALL /EDID:reset()
˂ mO /EDID:reset
Explanation: Calling this method switches all emulated EDIDs to factory default one. See the table in the
Factory EDID List
section.
>|<E
>|<F
>|<U
>:<U
>)
n
n
n
n
m
>)
n
HDMI-3D-OPT series – User's Manual