5. Software Control - Lightware Device Controller
5.9. Event Manager
The feature means that the device can sense changes on its ports and able to react
according to the pre-defined settings. The development idea of the Event manager
is based on users' feedbacks. In many cases internal events (such as signal present
or HDCP active) are necessary to display but it is not easy when the device is hard
to access (e.g. built under the desk). For more details and examples about Event Manager please visit our
website (www.lightware.com) and download Event Manager user's guide in the Downloads section.
The Event manager can be configured to perform an action if a condition has been detected. E.g. the desired
setup is that after a certain type of signal has been detected on I1 port, the port has to be switched to O1.
The settings can be done via the LDC in the Control/Events tab, or by LW3 protocol commands. Configurable
events number depends on the device what you are using actually.
Numerous new ideas and requests have been received in connection with the features and settings of the
Event manager since the first release. Therefore, the user interface has been re-designed and many new
functions implemented. The Event editor can be opened by pressing the Edit button at each Event.
There is a grey bar on the left of the Event panel in each line. If a condition and an action are set and the Event
is enabled, the bar is displayed in green.
Control menu, Event Manager tab
HDMI-3D-OPT series – User's Manual
The Event Editor
Press the Edit button in the desired Event line to open the Event editor window.
1
2
3
4
Event header
1
2
Condition header
3
Condition panel
4
Condition test
5
Delay settings
6
Action header
Action panel
7
8
Action test
5
The name of the Event is displayed. Type the desired name and press the Set
name button. The Event can be cleared by the Clear button. Use the tick mark
to enable/disable the Event.
If the condition is set, the description (white colored text) and the exact LW3
protocol expression (yellow colored text) can be seen. If the advanced mode
was used the description is "Custom condition".
The Wizard, the Advanced or the Link tool is available to set the condition.
The parameters and settings are displayed below the buttons.
The set condition can be tested to see the working method in the practice.
The action can be scheduled to follow the condition after the set time value.
If the action is set, the description (white colored text) and the exact LW3
protocol expression (yellow colored text) can be seen. If the advanced mode
was used the description is "Custom action".
The Wizard, the Advanced or the Link tool is available to set the action. The
parameters and settings are displayed below the buttons.
The set action can be tested to see the working method in the practice.