Fatal error codes
The display shows an alphanumeric code consisting of six
digits and/or letters. When messages are read out starting
300XXX the error occurred during the internal operational
check, if it is C10XXX it occurred during the self-test after the
machine was switched on.
• If necessary, call service.
Note
The displayed error codes refer only to the internal line voltage
of the machine.
300 800 or C10 800 - Fig. 106
Line voltage too low. Balancing is feasible if the motor can
drive the main shaft to the measuring speed. Wheel data may
be lost.
• Bring the line voltage to within a range of 115 - 120 V
AC.
300 801 or C10 801 - Fig. 107
Line voltage too high. Damage to the electronic unit of the
machine is likely!
• Turn off machine immediately.
Damage is not covered under warranty.
300 804 or C10 804 - Fig. 108
Line voltage too high. Damage to the electronic unit of the
machine is likely!
• Turn off machine immediately.
Damage is not covered under warranty.

Error messages by means of acoustic signals

Error messages can also be indicated by means of acoustic
signals. The service technician can locate and eliminate the
corresponding error by means of the number of tones, their
frequency and duration (long/short) and the length of the
pauses.
• Switch off the machine.
• Call service.