Entry of balancing mode and wheel size
1
ALU
a
AP1
b
ALU
c
ALU
d
42
24
+
-
AP2

7.2.5 Determing the position of the hidden weights

(Alu 3P)
Note
Enter rim width before determining the position of the weights.
Fig. 42 Scanning and input of the dimensions
1 Alu key
a Selection of balancing mode Alu 3P
b Measurement procedure
c Application position AP1
d Application position AP2
• To set the desired balancing mode press and hold the
Alu key (Fig. 42, item 1).
• Holding the key pressed rotate the wheel until mode
Alu 3P is shown (Fig. 42a - the left weight symbol is
displayed as long as the key is pressed). Release the
Alu key as soon as the desired balancing mode is read
out.
Recommendation
Clamp an adhesive weight in the weight holder of the gauge
with the cover film of the weight being in top position prior to
scanning the correction dimensions.
• To determine the gauge application position AP1, pull
the gauge arm for distance and diameter out of the
cabinet, apply the gauge on the rim in the center of the
weight position as shown in Fig. 42b, item AP1 and
hold in that position.
The symbol for the outer weight is viewed on the display (Fig.
42c).
• Approach the gauge to application position AP2 and
hold in that position.
The symbol for the inner weight is viewed on the display (Fig.
42d). An audible signal is given when the distance has been
stored.
• Return the gauge arm for distance and diameter to its
home position.
• Start the measuring run.
Operation manual geodyna 2600 EEWB703D