Hofmann geodyna 2600 Operation Manual page 10

Table of Contents

Advertisement

Controls and displays
1
2
ALU
FINE
INT
PROMATCH
= 0
RV-LIGHT TRUCK
12
1
2
ALU
3
FINE
INT
PROMATCH
4
= 0
RV-LIGHT TRUCK
5
6
13
10
3
4
5
inch mm
CALIBRATE
SPOKE
7
8
CALIBRATE
SPOKE
9
Fig.12 Display panel - left section
1 Direction indicator of left correction plane
2 Indicates when correction position in the left
correction plane has been reached.
3 Inch/mm
The unit of measurement (inch or mm) is chosen by using
the rim width key .
4 Rim width Symbol
Lights whenever width key is pressed.
5 Digital Display for left correction plane to show:
- rim width
- amount of unbalance of left correction plane
- amount of static unbalance
- error codes
- C codes
- balancing mode in plain language (upon operation of
ALU key)
- STO, RCL of wheel profiles
Note: Error codes are read out in both digital displays.
Fig. 13 Status LEDs
1 ALU: Any ALU balance mode is selected
2 FINE: FINE key is pressed (cancels supression of small
imbalances). Display changes to normal resolution as
soon as key is released.
3 INT: Patch Balance is selected. All special functions
(including FINE) are inactive and cannot be selected.
4 PRO MATCH is selected.
5
= 0 Compensation run has been carried out
6 RV/LIGHT TRUCK resolution is selected.
7 CALIBRATE: Operator calibration mode is entered or
programmable interval is reached.
The LED is automatically activated after 5000 measuring
runs and alerts the operator that operator calibration is
recommended. The LED remains on until the operator
completes the operator calibration.
8 SPOKE: Hidden spoke placement (HSP) mode is
selected.
9 Number of spokes
Number of spokes for hidden spoke placement. Holding
the SPOKE key pressed rotate the wheel to set the
number of spokes between 3 and 12.
Operation manual geodyna 2600 EEWB703D