Determination Of Distance And Diameter; Gauge For Distance And Rim Diameter; Automatic Determination Of Distance And Diameter; Manual Input Of Distance Rim/Machine - Hofmann geodyna 2600 Operation Manual

Table of Contents

Advertisement

AP1
4
37
1
ALU
38
Entry of balancing mode and wheel size

7.2.3 Determination of distance and diameter

For the balancing modes nor., Alu 1, Alu 2, Alu 3, Alu 4 and Alu
5 the correction dimensions are derived from the dimensions
by subtraction or addition of correction values.
3
Fig. 37 Gauge for distance and rim diameter
1 Scale for distance, mm only
- scale with 2 mm graduations 2
Gauge arm with pointer
3 Pointer
4 Reference edge for distance reading
2
The distance between left correction plane and machine and
the rim diameter are usually entered automatically using the
integrated gauge arm, but may also be entered by pressing
and holding the menu keys for rim diameter and distance and
rotating the wheel until the desired value is read out.
1

Automatic determination of distance and diameter

• Pull the gauge arm for distance and diameter (Fig. 37,
item 2) out of the cabinet, apply the gauge (Fig. 37,
item 3) on the rim flange as shown in Fig. 37, and hold
in that position.
An audible signal confirms that distance and rim diameter
have been stored automatically.
• Re-place the gauge arm in its home position.
Upon operation of the key the distance and the diameter can
be read out once again.

Manual input of distance rim/machine

If automatic determination of the distance rim/machine is not
possible (error code E92), the distance can be determined
manually in balancing modes normal, Alu 1, Alu 2, Alu 3, Alu 4
and Alu 5.
Attention
In balancing modes Alu 2P and Alu 3P manual input of the
distance rim/machine will produce an incorrect measurement
result.
• Pull the gauge arm (Fig. 37, item 2) out of the cabinet,
apply the gauge (Fig. 37, item 3) on the rim flange as
+
shown in Fig. 37 and hold in that position.
• Note the distance shown on the scale (Fig. 37, item 4).
• Return the gauge arm to its home position.
• Press and hold the key for distance (Fig. 38, item 1).
• Holding the key pressed, rotate the wheel to enter the
distance previously indicated on the scale.
• Release
By pressing the key the distance can be viewed once again.
Operation manual geodyna 2600 EEWB703D
t he key.
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents