Fatal Error Codes - Hofmann geodyna 2600 Operation Manual

Table of Contents

Advertisement

Turning on the machine
21
22
23
24
25
26
27
14
H82 - Fig. 21
The self-test was disturbed (e.g. by rotating the wheel). The
message is displayed for 3 seconds, after which the mea-
surement is repeated (max. 10 times), or aborted by pressing
the STOP key.
E3 - Fig. 22
Gauge arm for distance and rim diameter is not in home
position.
• Move gauge arm to its home position. Press the STOP
key.
E92 - Fig. 23
During the second attempt the gauge arm for distance and rim
diameter was still not in the home position. The gauge arm is
rendered inoperative.
• Wait 3 seconds, or press the STOP key to continue.
E145 - Fig. 24
The contents of both permanent memories are different (but
both contain valid data).

Fatal error codes

The self-test program has detected an error and displays an
alphanumeric code consisting of six digits and/or letters.
Note
The displayed error codes refer only to the internal line voltage
of the machine.
C10 800 - Fig. 25
Line voltage too low. Balancing is feasible if the motor can
drive the main shaft to the measuring speed. Wheel data may
be lost.
• Connect the machine to 115-120 V AC.
C10 801 - Fig. 26
Line voltage too high. Damage to the electronic unit of the
machine is likely!
• Turn off machine immediately.
Damage is not covered under warranty.
C10 804 - Fig. 27
Line voltage too high. Damage to the electronic unit of the
machine is likely!
• Turn off machine immediately.
Damage is not covered under warranty.
Operation manual geodyna 2600 EEWB703D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents