Special Balancing Operations - Hofmann geodyna 2600 Operation Manual

Table of Contents

Advertisement

1
43
X
0
1
3
2
44
Entry of balancing mode and wheel size
Fitting of balance weights
The weight for AP1 is a hammer-on weight and is attached at
12 o'clock to the main shaft after indexing the wheel, as in the
normal mode. The gauge arm stays in its home position.
2
3
The adhesive weight for AP2 is as described below:
• Select an adhesive weight and adjust it to the wheel
• Clean the position before attaching the adhesive
• Raise the gauge arm (Fig. 43, item 1) and pull the hold-
4
5
• Insert the adhesive weight (Fig. 43, item 3) into the
• Press the adhesive weight firmly into the gauge and
• Pull the gauge arm towards application position AP2.
The display shows the dimension for the first distance, which
decreases as the gauge is approached. At 0 ±1 an audible
signal is given to show that AP2 has been reached.
• Press the pedal of the main shaft lock to hold the wheel
• Swing the gauge arm out towards the rim and press the
• Swing the gauge arm in and return it to its home posi-
• Firmly press the adhesive weight on the rim by hand.

7.2.6 Special balancing operations

If none of the programmable balancing modes can be used:
• Measure the distance and the actual correction dimen-
• Press and hold the key (Fig. 44, item 1 - 3) and rotate
• Release the key as soon as the desired value is read
Operation manual geodyna 2600 EEWB703D
radius by bending.
weights.
ing ring of the gauge (Fig. 43, item 2) inwards.
gauge with the protective tape facing upwards to the
arrow (Fig. 43, item 4).
remove the protective tape from the weight.
in this position.
weight firmly against the rim using the ejector (Fig. 43,
item 5).
tion.
sions (center of gravity of balance weight to be at-
tached) directly on the wheel (Fig. 44).
the wheel to set the values.
out.