Fitting Of Balance Weights - Hofmann geodyna 2600 Operation Manual

Table of Contents

Advertisement

1
41
Entry of balancing mode and wheel size

Fitting of balance weights

• Select an adhesive weight for AP1 and adjust it to the
wheel radius by bending.
2
3
• Clean the position before attaching the adhesive
weights.
• Raise the gauge arm (Fig. 41, item 1) and pull the hold-
ing ring of the gauge (Fig. 41, item 2) inwards.
• Insert the adhesive weight (Fig. 41, item 3) into the
gauge with the protective tape facing upwards to the
arrow (Fig. 41, item 4).
4
5
• Press the adhesive weight firmly against the gauge and
remove the protective tape from the weight.
• Pull the gauge arm towards application position AP1.
The display shows the dimension for the first distance, which
decreases as the gauge is approached. At 0 ±1 an audible
signal is given to show that AP1 has been reached.
• Press the pedal of the main shaft lock to hold the wheel
in this position.
• Swing the gauge arm out towards the rim and press the
weight firmly against the rim using the ejector (Fig. 41,
item 5).
• Swing the gauge arm in and return it to its home posi-
tion.
• Firmly press the adhesive weight on the rim by hand.
Fit the second adhesive weight for AP2 in the same manner.
Operation manual geodyna 2600 EEWB703D