CX23-R and EX23-R
 4. Wait for the camera status LED to turn green, which indicates that the camera
has been reset. This may take up to two minutes.
NOTE
The location of the control button and LED status indicator depends on the
camera model. For information on specific models, refer to the Axis
documentation.
2.4   Setting up a remote power switch
A remote power switch allows the user to control the CX23-R power state without
using the power push button. This is useful in situations where the CX23-R unit is not
easily accessible to the test operator.
The remote power switch acts as a three-way household switch in conjunction with
the CX23-R power push button. Connect the 1-KAB2115-2 green and black wires to
two contacts of a single pole, single throw contact switch with sufficient current
rating (at least 10 A recommended).
NOTE
When remote switching capability is not needed, the green wire on the
1-KAB2115-2 power supply cable should be electrically isolated.
2.5   Powering from a vehicle
The following illustrates the recommended power connections for using a vehicle
electrical system as the SomatXR system power source. The included diagrams are
not intended to be complete, detailed instructions.
CAUTION
Connection to the positive power terminal without proper grounding may result in
a blown fuse and/or other damage to the SomatXR system.