  Transducer
CAN bus
database or raw message
*
Use quarter bridge adapter 1-SCM-R-SG1000-2, 1-SCM-R-SG120-2 or 1-SCM-R-SG350-2.
CX23-R and EX23-R
5.4.15   CAN devices
NOTE
To ensure normal operation, the CAN bus needs to be terminated at both ends
using appropriate termination resistors. The CX23-R, MX471B-R and MX840B-R
provide internal completion resistors between CAN H and CAN L that can be
enabled or disabled individually with software.
NOTE
The optional CAN power provided by the CX23-R is 1 A limited and the same
voltage as the input to the CX23-R.
a4275-8.0 en    HBM: public
CX23-R
MX840B-R
    ●   
connector 1
5   SomatXR hardware
MX471B-R
    ●   
database only