Triggered Zero Suppression; Up Sampler - HBM SomatXR CX23-R User Manual

Somatxr series ultra-rugged daq
Hide thumbs Also See for SomatXR CX23-R:
Table of Contents

Advertisement

CX23-R and EX23-R
from TRUE to FALSE. When the trigger channel is FALSE, the channel outputs
the same value as the input channel.
NOTE
If the trigger channel is initially TRUE, the channel outputs a system defined
value of zero until the trigger channel transitions to FALSE.
  Invert: If selected, the output logic is inverted. The channel latches the input data
value when the trigger channel transitions from TRUE to FALSE and holds this
data value until the trigger channel transitions from FALSE to TRUE.
4.4.22   Triggered zero suppression
The Triggered zero suppression computed channel generates an output channel that
zero suppresses the input channel when a trigger condition is satisfied.
NOTE
The Triggered zero suppression computed channel is designed primarily to
provide a reset for quadrature decoder channel outputs when a triggering event
occurs.
Suppression trigger and value
  Channel: Set the trigger channel used to suppress the input channel.
  Mode: Set the condition for suppressing the input channel.
 
When true: Suppress the input channel when the trigger channel is TRUE.
o
 
On false - true edge: Suppress the input channel when the trigger channel
o
transitions from FALSE to TRUE.
 
On true - false edge: Suppress the input channel after the trigger channel
o
transitions from TRUE to FALSE.
  Value: Enter the desired suppression value. The default value is zero.
4.4.23   Up sampler
The Up sampler channel increases the number of samples taken from the input
channel by a user-defined factor, enabling correlation of input data with that of a
channel with a higher sample rate on a point-for-point basis. Each input channel
sample repeats a number of times during the interval between the first sample and
the next one based on a conversion factor value. See
channel for information about simulating a lower sample rate.
  Factor: Enter an integer greater than zero as the up sample factor. This has the
effect of increasing the sample rate by the product of this integer factor. The
following example has a integer factor of three.