5   SomatXR hardware
  Transducer
Strain gage, full bridge
six-wire configuration
Strain gage, half bridge
five-wire configuration
Strain gage, quarter bridge
three- or four-wire configuration
92
The following table gives the descriptions for all LED states.
System LED
Green
Red
Orange
Orange flashing
--
--
--
--
5.3.5   MX411B-R Highly Dynamic Universal Module
Up to four (4) electrically isolated inputs can be connected to the MX411B-R module,
including strain gage and inductive bridges, standardized voltage and DC current
sources (20 mA) or current-fed piezoelectric (IEPE, ICP®) and piezoresistive
transducers.
a4275-8.0 en    HBM: public
Channel
Description
LED
--
System is error free
--
System error
Orange
System is not ready; boot procedure is
running
Orange
System is not ready; download is active
flashing
Green
Connection is error free
Green
TEDS data is valid
flashing
(LED flashes for 5 s)
Orange
Transducer identification/sensor scaling
is running
Red
No sensor connected
Channel error (incorrectly parametrized,
connection error, invalid TEDS data)
Overload of sensor supply
MX411B-R
*
    ●   
3-wire only
Wiring diagram
99
99
99
CX23-R and EX23-R