4   Setting up and running a test
CX23-R and EX23-R
4.1   Setting up a test
Set up tests in the Test Configuration section of the web interface. Perform the
following steps to set up a test.
 1. Create a test setup on the
computed channels and DataModes that the unit captures and processes during
a test run. The unit can store multiple test setups. CX23-R test setups can be
exported and imported on other CX23-R modules.
 2. Add input channels to the test setup on the
connected devices and imported CAN databases. For applicable transducer
types, sensor parameters can be easily defined using TEDS or imported HBM
sensor database files. For channels that need to be scaled, set the scaling
parameters and perform experimental scaling measurements.
 3. Create
Computed channels
channels or other computed channels.
 4. Create
DataModes™
4.2   Configuring input channels
4.2.1   Configuring TEDS sensors
To simplify input channel configuration, SomatXR MX modules support TEDS
sensors.
NOTE
TEDS sensors can be programmed using HBM catman®AP or MX Assistant.
For more information, refer to the software documentation.
TEDS sensors are shown in both the
  Hardware page: Expand an MX module. The connectors with TEDS sensors
connected are indicated by the TEDS sync icon (
  Input channels page: Click Add and select an MX module from the hardware
list. The connectors with TEDS sensors connected are indicated by the TEDS
sync icon (
).
NOTE
When a new MX module is connected or rebooted, the system runs through a
TEDS discovery process indicated by the TEDS discovery icon (
take several seconds.
When a channel is added to a connector with a TEDS sensor connected, the channel
parameters are configured based on the TEDS information. Channel parameters can
be manually edited, which is indicated by the TEDS edited icon (
a4275-8.0 en    HBM: public
4   Setting up and running a test
Test setup
page. Test setups define the channels,
Input channels
as needed to manipulate the data from transducer
to store channel and computed channel data.
Hardware
and
page based on the
Input channels
pages.
).
). This may
). If a TEDS