6.6 KNIFE TEMPERATURE ADJUSTMENT
NOTE: Infrared Thermometers are available for testing the Knife Blade temperature on
our equipment. The part number is 1722303, or use a Beaded Thermocouple.
1.
Check the Knife Temperature.
2.
If a temperature adjustment is necessary, plug machine in, turn it on, and close tray interlock.
3.
When machine goes to ready, press >1" and <1" at same time. Display will read "dd" for 2
seconds, and then go to "15" which is the debind time. Press >1" again, and display will read
"tt"for 2 seconds, and then go to "05", which is the currently programmed temperature
setting.
4.
To INCREASE the TEMPERATURE, press <1".
5.
To DECREASE the TEMPERATURE, press "DEBIND".
6.
Press the >1" to return machine to normal operation.
7.
Allow 6 or 7 minutes for the temperature to stabilize, and then retest the temperature.
8.
Make a test bind on both >1" and <1" binding speeds. Readjust temperature as necessary.
6.0 ADJUSTMENTS
6-6