Table C-14 (Cont.)
Device Status Codes (DDMMSSTD
Status Codes
Definition
AC
DMA not complete after EOF in data in phase (ACK not
clear soon enough).
BO
statu8(deinand) not cleared by clearing inode(DMA) at
start of status phase in DMA test.
B2
Target failed to set status phase in DMA test.
B4
Timeout waiting for DMA complete in status phase in
DMA test.
B6
No statusCdemand) following status phase in DMA test.
B8
Wrong interrupt following status in DMA test.
BA
Scd.cnt not zero following status in DMA test.
BC
DMA not complete after EOF in status phase (ACK not
clear soon enough).
CO
statusCdemand) not cleared by clearing mode(DMA) at
start of message in phase in DMA test.
G2
Target failed to set message in phase in DMA test.
C4
Timeout waiting for DMA complete in message in phase
in DMA test.
C6
No status(demand) following message in phase in DMA
test.
C8
Wrong interrupt following message in phase in DMA
test.
CA
Scd.cnt not zero following message in phase in DMA
test.
CC
DMA not complete after EOF in message in phase (ACK
not clear soon enoxigh).
DO
StatusCdemand) not cleared by clearing mode(DMA) at
end of DMA test.
D2
SCSI bus not free soon enough at end of DMA test.
c-14 Power-Up, Self-Test, and TEST 50 Status and ErrorCodes