TK50Z-GA controls and lights are described in Table 4-2 and
T^ble 4-3.
Before you insert a cartridge, make sure the load/unload button is
in the out (unload) position.
The red light in the load/unload button comes on for
approximately 4 seconds during the automatic power-up test.
When the red light goes off and the green light comes on, it is safe
to move the cartridge release handle.
If a cartridge is new, the tape drive performs a calibration
sequence that takes approximately 40 seconds. The green light
flashes rapidly and irregularly during calibration.
Caution Do not move the cartridge release handle unless the red light is off
and the green light is on.
Do not move the cartridge release handle while either light is
fUishing,
If the red light flashes rapidly at any time, press the load(unload
button four times. If the problem persists, do not attempt to use the
tape drive or remxive the cartridge. See Chapter 6.
Adding and Using Expansion Boxes 4-21