Running Self-Ifests - DEC VAXstation 3100 Owner's Manual

Table of Contents

Advertisement

• Network select button is set to wrong position. The correct
positions are in for ThinWire Ethernet or out for standard
Ethernet.
Faulty cable or loose connection.
No Ethernet cable (standard)
??
1
coco 0011.700E
This message indicates one or more of the following:
No cable is installed on the standard Ethernet connectors.
No loopback connector is installed on the standard
Ethernet port.
• Network select button set to wrong position. The correct
positions are in for ThinWire Ethernet or out for standard
Ethernet.
Faulty cable or loose connection.
Tb correct the problem, turn the system off (0), and then turn the
system back on (I ). If you still get the same error message, you
may have a hardware problem with your Ethernet module.
^,^1^
Note See operating system documentation for shutdown procedures
before turning your system off. Also, you should not turn off, halt,
or restart the system without notifying work group members.
See Section 6.1 for the correct order in which to turn your system
components off (0) and on ( I).
7.2 Running Self-Tests
This section describes how to run self-tests on your system.
Self-tests are used to display the status of the devices installed on
your system. Self-test diagnostic programs reside permanently in
the Model 48 read-only memory (ROM).
lb test a device in your Model 48 system, follow these steps:
1
Use Table 7—1 to find the number or letter identifier for the
device you want to test.
Running Diagnostics 7-5