Monochrome Video Circuits (Mono; Time-Of-Year Clock (Clk - DEC VAXstation 3100 Owner's Manual

Table of Contents

Advertisement

C.I
Monochrome Video Circuits (MONO)
Error code format: OOOOJXXXX
where XXXX is one of the codes listed in Table C-1.
Table C-1
Monochrome Video Error Codes (OOOO.XXXX)
Error Codes
Definition
0001
No error.
0010
End of frame bit not set in interrupt pending register.
0020
End of frame failed to set for second time.
0040
End of frame failed to set for third time.
0080
No end of frame interrupt seen.
0100
Wrong IPL level for EOF interrupt.
0200
Interrupt request failed to clear interrupt pending
register bit.
0400
End of frame interrupt did not occur.
0800
Error dtiring cursor test
C.2 Time-of-Year Clocic (CLK)
^
Error code format: OOOOJCKXX
where XXXX is one of the error codes listed in Table C-2.
Table C-2
Time-of-Year Clock Error Codes (OOOO.XXXX)
Error Codes
Definition
0001
No error.
0003
Tell dispatcher to check time at the end of testing.
0004
Invalid time set.
0005
Clo(^ has not been reset since the last time battery
voltage level was low.
0010
Failure in time-of-year test.
0020
Vrt bit failed to set after it was read the first time.
0040
Battery voltage level was down during the clock test.