Restarting The System After Running Tests - DEC MicroVAX 3100 Owner's Manual

Table of Contents

Advertisement

»>
TEST 76
/Return/
KA41
RDRXfmt
VSfmt_QUE_unitno
(0-3)?
2
. .
VSfmt_VUE_RXmedtyp
(1=RX33),
(2=RX23) ?
2
VSfmt_QUE_RUsure
(DUA2 1/0) ?
1
~
VSfmt_sts_FMTing . . . . . OK
Vsfmt STS CKRXfmt . . . . . OK
VSfmt RES Succ
.. Enter 2 to format a diskette.
Enter 2 to format a diskette.
~
Enter 1 to continue formatting, or 0 to discontinue formatting.
The diskette has been formatted.
6.8 Restarting the System After Running Tests
While running any of the tests or procedures in this chapter, your system
is in console mode. To resume normal operation, you must reenter program
mode. The two ways to do this are:
1.
Enter BOOT at the console prompt and press RETURN. The system
then searches each device in turn for operating system software.
2. Enter BOOT followed by a space and the name of the device that
contains operating system software and then press RETURN, as shown
in the following example:
> > >
BOOT DKA300
/
Return
I
»>
This procedure lets the system boot the operating system software
immediately, without searching for the software.
For more information, see your operating system documentation.
6-18 MicroVAX 3100 and VAXserver 3100 Owner's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vaxserver 3100

Table of Contents