Specifications
Continued
Description
Input Voltage Range
Input Frequency
Nominal Output Bus
(@ 400 / 460 input)
Nominal Phase Current ("10%)
Peak Phase Current ("10%);
1.25s +0.25s/--0s
¡
Nominal Output Power
Output Frequency
Efficiency
Nominal Switching Frequency
Current Loop Bandwidth
Velocity Loop Bandwidth
Mounting
Package Size
Operating Altitude
Operating Temperature
Rated Storage Temperature
Humidity
Class of Protection (Enclosure)
Shock
Vibration
Valid for zero current initial condition.
¡
All values at ambient temperature of 25#C unless otherwise stated.
For safe operation, allow a clearance distance between each control and on all sides of each control.
MN1276
Unit
Nominal
VAC
Minimum
Maximum
Hz
Nominal
VDC
Minimum
Maximum
A
RMS
A
RMS
KVA
Hz
%
KHz
Hz
Hz
--
--
Feet
(Meters)
#C
#C
%
FP4
FP4
A02TB
A05TB
460 @ 60Hz / 400 @ 50Hz
2.5
5
5
10
1.9
3.8
10 to 200 (software selectable)
G
G
To 3300 feet (1000 meters). Derate the continuous and
peak output current by 1.1% for each 330 feet (100
meters) above 3300 feet.
+0 to 40. Above 40#C, derate the continuous and peak
output current by 2.5% per #C above 40#C. Maximum
ambient is 50#C.
10% to 90% non-condensing
10G (according to DIN IEC 68--2--6/29)
1G @ 10 -- 150 Hz (according to DIN IEC 68--2--6/29)
FP4
FP4
A07TB
A15TR
A20TR
400 / 360
528 / 480
50/60 "5%
565 / 678
509 / --
-- / 746
7.5
15
15
30
5.7
11.4
0 -- 500
>95
8.0
1200
Panel
G
H
--25 to +70
IP20
Specifications & Product Data 7-3
FP4
FP4
A27TR
20
27.5
40
55
15.2
20.9
H
H