Baldor FPX A05T Installation & Operating Manual page 19

Flex+drive servo control
Table of Contents

Advertisement

Figure 3-9
X1 - Power Connector
Earth
Input Power
L
AC Line
N
Neutral
U
Motor lead "U"
Motor
V
Motor lead "V"
W
Motor lead "W"
Dynamic Brake
R1
Dynamic Brake
R2
Dynamic Brake
(Regen Resistor)
+24V Customer
FPxAxxxx-xxx3
0V
Provided
only ¡
Terminal tightening torque is
0.5 lb-in (0.6Nm)
X3 - Control Signals & Digital I/O
1
CMD+
2
CMD-
3
AGND
4
Fault Relay+
5
Fault Relay--
6
CIV
7
CREF
8
CGND
9
Enable
10 MaI3
11 MaI4
12 Quit
13 Fault Reset
14 Home Flag
15 Trigger
16 MaI1
17 MaI2
18 MaO1
19 MaO2
20 DrOK
Important:
¡
FPxAxxxx-xxx3 only.
A separate 24VDC supply to the "Logic Power" input is required for
operation. An FPxAxxxx-xxx3 control will not operate without 24VDC
on this input.
3-8 Receiving & Installation
Connector Locations (Single Phase Controls)
X1
NC
L
N
U
V
W
R1
R2
+24V
0V
DB On
The holes in the top and
Monitor
bottom of the enclosure
AS1
are for cable clamps. Be
1
sure to use an M4 bolt
2
3
12mm in length. Longer
4
bolts may short circuit the
5
6
electrical components
7
8
inside the control.
Off/On
X9 - Encoder Feedback Option
Ready
1
2
3
4
5
6
7
8
RS232
1 Reserved 1 TX-
2 R
x
3 T
x
4 DTR
5 DGND
6 DSR
7 RTS
8 CTS
9 +5V
X7 - Simulated Encoder Output
1 CHA
2 CHB
3 CHC
4 Reserved 9 Reserved
5 DGND
1 REF
2 COS
3 SIN
4 Reserved 9 Reserved
5 AGND
Note:
X3
(only - -Exxx versions)
CHA+
9
HALL3+
CHB+
10 HALL2+
CHC+
11 +5VDC
HALL1+
12 N.C.
HALL1--
13 DGND
CHA--
14 HALL3--
CHB--
15 HALL2--
CHC--
X6 - RS232 / 485
RS485
Data
2 TX+
Data
3 RX+
4 RX-
5 DGND
6 RTS-
7 RTS+
8 CTS+
9 CTS-
6 CHA--
7 CHB--
8 CHC--
X8 - Resolver Input
6 REF--
7 COS--
8 SIN--
Reserved means no
connection is required and
no connection should be
made to this terminal. It is
reserved for future use.
MN1276