X3 Digital Inputs Continued
Pin
Signal
Number
Name
X3-9
Enable
X3-10
MaI3
X3-11
MaI4
X3-12
Quit
X3-13
Fault Reset
X3-14
Home Flag
X3-15
Trigger
X3-16
MaI1
X3-17
MaI2
Signal Name Opto Input Signal Definition
Enable
CLOSED allows normal operation.
OPEN disables the control and motor coasts to a stop.
Quit
CLOSED cancels any move in progress and the motor will decelerate (at
parameter MOT.ACC) to rest. This input is edge triggered.
OPEN allows position mode operation.
Fault Reset
CLOSED allows the control to be cleared or "Reset" for any of the following four
fault conditions (provided that the cause of the fault has been removed):
$ Overvoltage
$ Undervoltage
OPEN allows normal operation.
Home Flag
Edge triggered input that is used to sense the "Home Position".
Trigger
Rising edge triggered input that initiates a "point-to-point move". The move is
defined by the machine inputs MaI1 - 4.
MaI1,2,3,& 4
Four machine inputs are provided. These may be used with the internal PLC
software program. The internal PLC software can cause an event to occur based
on the presence of these inputs.
However, more often these inputs are used to define up to 15 preset positions or
point to point moves. The 16th move is always home. With this method, it is not
possible to use hardware limits (CW and CCW). Therefore, software limits must
be used. Software limits are only active after a homing routine has completed.
Note: Hardware limit switches may be wired in series with the "Enable" input
MN1276
Table 3-3 Opto Input Signal Conditions
Switch = Closed (active)
Drive enabled.
Machine Input 3 = Logical 1
Machine Input 4 = Logical 1
Stop positioning mode operation
Fault Reset is active (reset control).
Home flag = closing (rising) edge
Trigger = closing (rising) edge
Machine Input 1 = Logical 1
Machine Input 2 = Logical 1
$ Electronic Fusing
$ Resolver Fault
X3--9. Then if a limit is reached, the control will be disabled.
Switch = Open (not active)
Drive disabled.
Machine Input 3 = Logical 0
Machine Input 4 = Logical 0
Positioning mode is operating
Fault Reset is not active.
Home flag = opening (falling) edge
Trigger = opening (trailing) edge
Machine Input 1 = Logical 0
Machine Input 2 = Logical 0
Receiving & Installation 3-13