Baldor FPX A05T Installation & Operating Manual page 53

Flex+drive servo control
Table of Contents

Advertisement

Ready Monitor
Red
A
EEPROM checksum error.
Red
c
Velocity data in the EEPROM failed.
Green
C
CAN bus problem detected.
Red
C
CAN bus problem detected.
Green
d
Control Disabled.
Green
E
Following Error.
Green
F
Fatal Following Error.
Green
H
Hold-Position mode.
Green
J
Jog mode.
Red
L
Both limit switches active.
Green
P
In Position.
Red
U
EPROM version fault.
Red
u
EEPROM version fault.
It is important to connect the motor leads U, V and W correctly at the X1 connector
of the control. Incorrect wiring can cause erratic operation including moves at
peak force until the overcurrent limit trips. This will result in a display of "7" and a
"6" on the monitor. If erratic movement of the motor occurs, turn off power
immediately and check the connections of the motor, hall sensors and encoder.
6-2 Troubleshooting
Table 6-1
Operating Mode Indications Continued
Status
Cause
The personality must be downloaded to
EEPROM and reset the control. If problem
remains, contact Baldor.
The velocity data must be downloaded to
EEPROM and reset the control. If problem
remains, contact Baldor.
("C" blinking) A communication error on the
CAN bus exists. The control is still
connected to the CAN bus.
("C" blinking) A communication error on the
CAN bus exists. The control will attempt
resynchronization to establish the CAN bus.
Disable mode activated by hardware or
software.
The following error exceeded the user
defined value of the Following Error Band.
This error is not stored and goes away when
the following error is reduced to within limits.
The following error exceeded the user
defined value of the Following Fatal Error.
The following error preset level is
"Operation Mode ( Pulse Follower"
This error is stored and must be cleared by
the operator, but operation continues as
long as the error is less than "2
Hold mode activated by hardware or
software.
Jog mode activated by hardware or software.
Defective or missing limit switch or wiring.
The following error is less than the user
defined preset value.
The personality must be downloaded to
EEPROM and reset the control.
The personality must be downloaded to
EEPROM and reset the control.
15
("32768).
MN1276

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents