Baldor FPX A05T Installation & Operating Manual page 11

Flex+drive servo control
Table of Contents

Advertisement

Control Inputs Opto isolated inputs are single ended, user selectable and active high or low:
Control Outputs
One normally closed relay contact provides a dedicated "Drive Ready" output.
Two opto isolated outputs are single ended, active low and are current sinking.
Either output can be assigned to one of the following:
Simulated Encoder Output
Resolver Feedback
The resolver feedback signal is converted to PPR (pulses per revolution) by a
Resolver to Digital Converter. A position controller uses position feedback
The resolution of the simulated encoder output is software controlled with the
following available resolutions:
Note: For speeds above 6000 RPM, resolution is limited to 1024PPR maximum.
Encoder Feedback
When encoder feedback is used, the encoder input signal is buffered and provided
at the simulated encoder output.
2-2 Product Overview
Enable
Quit
Fault Reset
Home Flag
Trigger
In Position
CW Warning
CCW Warning
Following Error Flag
Following Error Warning
I
t Warning
2
512 PPR, 1024 PPR, 2048 PPR or 4096 PPR
Machine Input 1
Machine Input 2
Machine Input 3
Machine Input 4
Machine Input 1
Machine Input 2
Machine Input 3
Machine Input 4
Drive Over Temperature
MN1276