13.3 Overview of setting parameters and technical design

Measuring point:
Flowmeter model:
Order no.:
Measured medium temp.:
Lining:
C
:
zero
Parameters
Prog. Protection code:
Language:
Flowmeter sensor
Nominal size:
Q
:
max
Pulse factor:
Pulse width:
Low cut-off setting:
Damping:
Noise reduction
Density:
Unit Q
.:
max
Unit totalizer:
Max. alarm:
Min. alarm:
Contact output:
Contact input:
Current output:
I
with alarm:
out
Detector e. pipe:
Calibrate e. pipe:
Alarm e. pipe:
I
with empty pipe:
out
Totalizer function:
Display line 1:
Display line 2:
Display line 3:
Display line 4:
Operating mode:
Flow direction:
Directional display:
Pulse output:
Communication:
Diagnostics
Min-Max threshold
monitoring
Error (E)
Warning (W)
D184B140U02
Device no.:
Electrodes:
C
:
Span
Setting range
................
0-9999 (0 = factory setting)
................
e.g., German, English, French, etc.
see name plate or the submenu "System Data / Flowmeter Primary"
................
................
DN 1 ... DN 1000
................
0.05 Q
................
Pulse / phys. unit
................
0,100 ... 2000 ms
................
0 ... 10% of flow range end value
................
0.2 (0.07) ... 20 seconds
................
OFF / 1 / 2/ 3 / 4
................
0.01 g/cm
................
e.g., l/s, l/min, l/h, hl/s, hl/min, hl/h, etc.
................
e.g., l, hl, m
................
%
................
%
................
Max. alarm, Min. alarm, Max./Min. alarm, General alarm, Empty pipe, etc.
................
External zero return, Totalizer reset, External system zero, no function
................
0/4 ... 20 mA, 0/2 ... 10 mA, 0 ... 5 mA, 0 ... 10-20 mA, 4 ... 12 ... 20 mA
................
0 %, 103 %, 3.8 mA, Low, High
................
ON / OFF
................
0 ... 10000
................
ON / OFF
................
0 %, 103 %, 3.8 mA, Low, High
................
Standard, difference totalizer
................
Q (%), Q (unit), Q (mA), counter F/R, TAG number, blank line, bar graph
................
Q (%), Q (unit), Q (mA), counter F/R, TAG number, blank line, bar graph
................
Q (%), Q (unit), Q (mA), counter F/R, TAG number, blank line, bar graph
................
Q (%), Q (unit), Q (mA), counter F/R, TAG number, blank line, bar graph
................
Standard / Piston Pump / Fast
................
Supply/Return, forward
................
Standard, inverse
Active
Passive
HART
PROFIBUS PA
Value
Coil current AC
Coil resistance
Coil insulation resistance
Electrode voltage
Signal-to-noise ratio
TAG no.:
Transmitter type:
Order no.:
Power supply:
Exciter frequency:
System zero point:
DN ... 1 Q
DN
max
max
3
... 5.0 g/cm
3
3
, igal, gal, etc.
FOUNDATION Fieldbus
E/W
Min.
Max.
Value
Coil voltage DC
Coil temperature
DAC value
Electrode balance
Magnetic linearity
FSM4000
Appendix