ABB ME ASURE ME NT & AN AL YT ICS | D AT A SHE ET
FSM4000
Electromagnetic flowmeter

Advertisement

Table of Contents
loading

Summary of Contents for ABB FSM4000

  • Page 1 — ABB ME ASURE ME NT & AN AL YT ICS | D AT A SHE ET FSM4000 Electromagnetic flowmeter...
  • Page 2: General Properties

    Measurement made easy The ultimate solution for the most demanding applications — Outstanding performance • The FSM4000 takes on the task where all other flowmeters fail. — FSM4000 for optimal operational security in all demanding applications • Sludges with high level of solids •...
  • Page 3 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — Overview – models Housing material Alu. Housing, Series 4000 Stainless Steel Housing, Series 2000 Fixed Flange Fixed Flange Wafer type Variable Connections 1) Welded spud 3) Pipe fitting 2) Tri-clamp 4) Male thread...
  • Page 4 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Overview – models Approvals Model number SE41F SE21F SE21W SE21_* Hygienic and sterile — CIP/SIP capable 3A, CIP/SIP capable requirements Pressure Equipment Directive Conformity assessment in accordance with category III, fluid group 1 97/23/EC CRN (Canadian Reg.
  • Page 5: General Data

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — General data Grounding Measuring accuracy Reference conditions in accordance with EN 29104 The grounding of the flowmeter sensor is essential for both safety reasons, and to ensure trouble-free operation of the Measuring medium 20 °C (68 °F) ±2 K...
  • Page 6: Mounting Position

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … General data Mounting position Inlet and outlet sections Figure 5: Mounting position Vertical installation for measuring abrasive materials, 1 Double manifold 2 Turn-off device preferably with flow in upward direction. For a horizontal installation, the meter tube must always Figure 4: Inlet and outlet section, turn-off devices be completely filled with the measuring medium.
  • Page 7: Mounting With Pipe Vibration

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Free inlet or outlet Mounting with pipe vibration Figure 6: Free inflow and outflow For a free outflow, do not install flowmeter at the highest point of the piping or on its outflow side, since the measuring tube may run empty, creating air bubbles.
  • Page 8: Installation In Piping With Larger Nominal Diameter

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … General data Installation in piping with larger nominal diameter 1 Reducer Figure 10: Using reducers Determine the resulting pressure loss when using reducers: 1. Determine diameter ratios d/D. 2. .Determine the flow velocity based on the flow rate nomogram (Figure 11).
  • Page 9 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Nominal diameter, nominal pressure, measuring range Nominal diameter Standard Min. flow velocity measuring range Max. flow velocity measuring range pressure rating 0 to 0.5 m/s 0 to 10 m/s ¹⁄₁₀ up to l/min 0.0529...
  • Page 10 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … General data Flange design and pressure rating Nominal diameter Flange Material Nominal diameter Flange Material 3 to 25 Stainless steel or 40, 63, 100 bar Stainless steel or 10, 16, 25, 40, 63, (¹⁄₁₀...
  • Page 11 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Flow rate nomogram The volume flowrate is a function of the flow velocity and the diameter of the flowmeter. The flowrate nomograph indicates the flowrate range for a specific flowmeter nominal diameter and which flowmeter nominal diameters are suitable for a specific flowrate.
  • Page 12 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — Model SE41F Specifications Temperature graph Min. permissible pressure as a function of measuring medium temperature Liner Nominal diameter Operation Operation mbar abs Hard rubber 15 to 1000 < 90 °C (194 °F) (1/2 to 40″)
  • Page 13: Storage Temperature

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Storage temperature −20 to 70 °C (−4 to 158 °F) IP rating in accordance with EN 60529 IP 65/IP 67 IP 68 (option) Pipe vibration according to EN 60068-2-6 Transmitter • In the range of 10 to 55 Hz, max. deflection 0.15 mm Sensor •...
  • Page 14 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE41F Dimensions Flange DN 3 to 100 (¹⁄₁₀ to 4”), aluminum sensor housing (shell housing) All specified dimensions and weights are in mm (in) or kg (lb). The specified weights are approximate figures. The maximum weight is always provided.
  • Page 15 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Dimensions – flange device, aluminum sensor housing (shell housing) Nominal Process connection Weight diameter DN 40 (1 ½”) EN 1092-1 , PN 10 to 40 150 (5.91) 21 (0.83) 200 (7.84) 92 (3.62) 262 (10.3)
  • Page 16 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE41F Flange DN 125 to 400 (6 to 16”), aluminum sensor housing (shell housing) All specified dimensions and weights are in mm (in) or kg (lb). The specified weights are approximate figures. The maximum weight is always provided.
  • Page 17 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Dimensions – flange device, aluminum sensor housing (shell housing) Nominal Process connection Weight diameter DN 250 (10") EN 1092-1, PN 10 395 (15.55) 30 (1.18) 450 (17.72) 198 (7.80) 413 (16.26) 427 (16.81) 349 (13.74)
  • Page 18 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE41F Flange DN 450 to 600 (18 to 24”), steel sensor housing All specified dimensions and weights are in mm (in) or kg (lb). The specified weights are approximate figures. The maximum weight is always provided.
  • Page 19: Remote Mount Design

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Flange DN 700 to 1000 (28 to 40”), steel sensor housing All specified dimensions and weights are in mm (in) or kg (lb). The specified weights are approximate figures. The maximum weight is always provided.
  • Page 20 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE41F Flange DN 25 to 200 (1 to 8”), high pressure design, aluminum sensor housing (shell housing) All specified dimensions and weights are in mm (in) or kg (lb). The specified weights are approximate figures. The maximum weight is always provided.
  • Page 21 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Dimensions - flange device, aluminum sensor housing (shell housing) Process connection Plan Weight 80 (3″) EN1092-1 PN63 (8.46) (2.99) (13.39) (44) EN1092-1 PN100 (9.06) (2.95) (13.39) (10.98) (4.25) (11.54) (8.46) (4.09) (53) ASME B16,5, CL 600 (8.23)
  • Page 22 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE41F Ordering information FSM4000 SE41F with welded Flange, Liner Material Thick-PTFE / PTFE / PFA / ETFE Main order number SE41F- XXX Electromagnetic Flowmeter FSM4000 Liner Material / Meter Size...
  • Page 23 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Main order number Electromagnetic Flowmeter FSM4000 SE41F- XXX Liner Material / Meter Size Thick PTFE / DN 200 (8 in) Thick PTFE / DN 250 (10 in) Thick PTFE / DN 300 (12 in)
  • Page 24 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE41F Main order number SE41F- XXX Electromagnetic Flowmeter FSM4000 Measuring Electrodes Material / Grounding Electrodes Hastelloy C-4 (2.4610) / Without Hastelloy B-3 (2.4600) / Without AISI 316Ti SST (1.4571) / Without...
  • Page 25 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Main order number SE41F- XXX Electromagnetic Flowmeter FSM4000 Certificates PED Standard Material certificate 3.1 acc. EN 10204 with pressure test acc. AD2000 Pressure test acc. AD2000 Inspection certificate 3.1 acc. EN 10204 Calibration Certificates...
  • Page 26 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE41F Main order number Electromagnetic Flowmeter FSM4000 SE41F- XXX Signal Cable Length Without cable 5 m (16 ft) 10 m (33 ft) 20 m (66 ft) 30 m (100 ft)
  • Page 27 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Additional order number Additional order number Electromagnetic Flowmeter FSM4000 SE41F- Calibration 2 points (standard) 3 point standard calibration Witnessed calibration, 5 calibration points 5 point calibration acc. ISO17025 Language of Documentation German English...
  • Page 28 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — Model SE21_ Specifications Minimum permissible absolute pressure Sensor material Liner Nominal diameter Liner Electrode material Electrode design Operation Operation mbar abs °C Standard Others Standard Others 3 to 100 ≤ 130 °C Hast.-C4...
  • Page 29 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Storage temperature JIS B2210−10K wafer type −25 to 70 °C (-13 to 158 °F) Nominal Material IP rating in accordance with EN 60529 diameter DN [bar] • IP 67 32 to 100 1.4404 (316 L), −40 to 130 °C...
  • Page 30 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ Material load for wafer type design model SE21W Liner: PFA wafer type A PN 40/CL 300 C PN 16/CL 150 B PN 25 D PN 10 Figure 23: Wafer type design model SE21W *) Higher temperatures are allowed for CIP/SIP cleaning for limited time periods, see Table ‘Maximum permissible cleaning temperature’.
  • Page 31 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Dimensions Model SE21F Stainless steel housing, flange according to DIN / EN 1092-1, DN 3 to DN 40; ASME B16.5, 1/10 to 1 1/2” 1 Cable gland M20 x 1.5 or NPT 2 Number of holes N Figure 24: Dimensions in mm (in) Flange dimensions acc.
  • Page 32 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ Flange dimensions acc. to ASME B16.5, liner PFA Weight kg approx. ¹⁄₁₀ to ⁵⁄₁₆ CL 150 88.9 60.3 42.0 15.9 18.0 ⅜ , ½ 88.9 60.3 34.8 15.9 12.6 ¾...
  • Page 33 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Stainless steel housing, flange according to DIN / EN 1092-1, DN 50 to DN 100; ASME B16.5, 2 to 4″ 1 Cable gland M20 x 1.5 or NPT 2 Number of holes N Figure 25: Dimensions in mm (in) Flange dimensions acc.
  • Page 34 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ Flange dimensions acc. to ASME B16.5, liner PFA Weight kg approx. CL 150 2½ CL 300 2½ Weight lb approx. CL 150 7.87 3.94 5.98 4.76 3.90 0.75 0.16 0.91...
  • Page 35 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Model SE21W Stainless steel housing, wafer type DN 3 to DN 100 (¹⁄₁₀ to 4”) DN 3 to DN 40 (¹⁄₁₀ to 1½”) DN 50 to DN 100 (2 to 4”) 1 Cable gland Pg 13.5 or NPT...
  • Page 36: Mounting Bracket (Optional)

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ DN (inch) Weight 1) 2) 1) 3) ØC ØDi ØD approx. 3 (¹⁄₁₀) 4 (⁵⁄₃₂) 6 (1/4) 8 (⁵⁄₁₆) 10 ⅜) 10 to 40 15 (½) CL150 CL300 20 (¾) 25 (1) 32 (1¼)
  • Page 37: Hole Pattern

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Model SE21_ Variable process connection DN 3 to DN 40 (¹⁄₁₀ to 1½”) DN 50 to DN 100 (2 to 4”) 1 Cable gland Pg 13.5 or NPT 4 Hole pattern 2 Hole pattern shaft holes...
  • Page 38 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ DN (inch) Weight kg approx. ØD Lpipe Lpipe 3 to 10 (¹⁄₁₀ to ⅜) – 15 (½) – 20 (¾) – 25 (1) – 32 (1¼) – 40 (1½) –...
  • Page 39 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Adapter for variable process connections DN 3 to 100 (1/8” to 4”) All specified dimensions and weights are in mm (in) or kg (lb). 1 Pipe fitting in accordance with DIN 11851 2 Tri-clamp Figure 28: Adapter for variable process connections DN 3 to 100 Threaded pipe connection in acc.
  • Page 40 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ Tri-clamp Nominal Pressure rating In accordance with DIN 32676 In accordance with ASME BPE diameter Ø Da Ø Di Series Weight Process Ø Da Ø Di Weight dimensions DN 3 to DN 10 See the chapter 163 (6.42)
  • Page 41 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L 1 Welded spud 3 Male thread Figure 29: Adapter for variable process connections DN 3 to 100 Welded spuds Nominal Pressure rating In accordance with DIN 11850 In accordance with ISO 1127 In accordance with SMS Weight diameter Ø...
  • Page 42 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ Welded spuds Nominal Pressure rating In accordance with DIN EN ISO 2037 In accordance with DIN 2463 Weight diameter Ø Da Ø Di Ø Da Ø Di DN 3 to DN 10 See chapter 127 (5.0)
  • Page 43: Ordering Information

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Ordering information FSM4000-SE21, remote, welded flange, 2000 series stainless steel housing Main order number SE21F- X Electromagnetic Flowmeter FSM4000 Process Connection Welded flange DIN 2501 / ASME Liner Material / Meter Size PFA / DN 3 (1/10 in)
  • Page 44 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ Main order number Electromagnetic Flowmeter FSM4000 SE21F- X Temperature Range Standard design (<= 130 °C [266 °F]) Certificates PED Standard Material certificate 3.1 acc. EN 10204 with pressure test acc. AD2000 Pressure test acc.
  • Page 45 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Main order number SE21F- X Electromagnetic Flowmeter FSM4000 Signal Cable Length Without cable 5 m (16 ft) 10 m (33 ft) 20 m (66 ft) 30 m (100 ft) 40 m (131 ft)
  • Page 46 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ Additional order number Additional order number Electromagnetic Flowmeter FSM4000 SE21F- Calibration 2 points (standard) 3 point standard calibration Witnessed calibration, 5 calibration points 5 point calibration acc. ISO 17025...
  • Page 47 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L FSM4000-SE21, Wafer Type, Variable Process Connections, Liner Material PFA Main order number Electromagnetic Flowmeter FSM4000 SE21- X Process Connection Wafer type Weld stubs DIN 11850 Weld stubs DIN 2463 Weld stubs ISO 1127...
  • Page 48 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ Main order number SE21- X Electromagnetic Flowmeter FSM4000 Pressure Rating PN 10 PN 16 PN 40 ASME CL 150 ASME CL 300 Material of Process Connection Without AISI 316Ti SST (1.4571) AISI 316L SST (1.4404)
  • Page 49 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Main order number SE21- X Electromagnetic Flowmeter FSM4000 Name Plate Language / Type German / Adhesive foil English / Adhesive foil French / Adhesive foil German / Stainless steel English / Stainless steel...
  • Page 50 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Model SE21_ Main order number Electromagnetic Flowmeter FSM4000 SE21- X Excitation Cable Length Without cable 5 m (16 ft) 10 m (33 ft) 20 m (66 ft) 30 m (100 ft)
  • Page 51: Mounting Accessories

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — Mounting accessories Wafer type accessories Depending on the nominal diameter and nominal pressure, the following accessories are available: bolts, nuts, spring washers. Gaskets are not included in the accessories. Designation Nominal diameter...
  • Page 52: Weld-In Adapter

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Mounting accessories Weld-in adapter For sensors with welded spud connection, welding adapters are available. Material Nominal diameter Ordering number Stainless steel 1.4301 (AISI 304) DN 3 to DN 10 (1/10 to 3/8 in.) D413C470U01 DN 15 (1/2 in.)
  • Page 53: Specifications

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — Transmitter Specifications Vibration In accordance with IEC 60068-2-6 (03/95), grouping of devices according to table C2 for general industry applications. No additional effect on the following levels of vibration. Frequency range 10 to 55 Hz; amplitude max. 0.15...
  • Page 54 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Transmitter Forward flow/reverse flow measurement Parameter configuration Flow direction is indicated by direction arrows in the display The display supports several languages (German, English, and over the contact for external signaling. The contact French, Finnish, Swedish, Italian, Spanish, Dutch or Turkish), output can also transmit this information.
  • Page 55 Electrode balance sensors over 20 years old. Occasionally, an adapter board Quality (signal-to-noise ratio) may be required (for details, see the FSM4000 operating instructions). The parameters can be checked for min.-max. errors. If the The following flowmeter sensors are supported:...
  • Page 56: Digital Communication

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Transmitter Inputs/Outputs Digital communication HART® protocol DC output (terminals 31, 32) The device is registered with the HART Communication The following functions can be selected in the software: Foundation. • 0 to 20 mA load ≤ 560 Ω...
  • Page 57: Bus Address

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L PROFIBUS PA protocol Bus address The interface conforms to Profile 3.0 (PROFIBUS standard, EN 50170, DIN 19245 [PRO91]). In the case of devices with a PROFIBUS PA interface, check the bus address prior to commissioning. If no specifications Note exist to the contrary, the address is set to 126.
  • Page 58 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Transmitter FOUNDATION Fieldbus® (FF) Note Bus address The FOUNDATION Fieldbus® protocol is an unsecured The bus address is automatically assigned or can be set in protocol, as such the intended application should be the system manually.
  • Page 59: Electrical Connections

    White shielded 2 x 1 mm2 CE type 227 TEC 74 o Shielded signal cable: ABB order no. D173D147U01, 10 m included in shipment, standard ABB order no. D173D025U01, 10 m included in delivery 7 Power supply Low voltage: 100 ... 230 V AC, terminals L, N, Extra-low voltage: 20.4 ...26.4 V AC;...
  • Page 60: Power Supply

    White shielded 2 x 1 mm2 CE type 227 TEC 74 o Shielded signal cable:: ABB order no. D173D025U01, ABB order no. D173D147U01, 10 m included in shipment, standard 10 m included in delivery 7 Power supply p with preamplifier (always at DN 3 to DN 8 [¹⁄₁₀ to ⁵⁄₁₆”]) Low voltage: 100 to 230 V AC, terminals L, N, Extra-low voltage: 20.4 to 26.4 V AC;...
  • Page 61 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Retrofit for model 10D1422: DN 3 to DN 1000 (¹⁄₁₀ to 40”); model 10DI1425 and 10DS3111A-E: DN 500 to DN 1000 (20 to 40”) S4 transmitter (wall mount housing) Sensor 1 Functional ground (busbar) 7 Shielded signal cable: ABB order no.
  • Page 62 2 x 1 mm2 CE type 227 TEC 74 p With preamplifier (always at DN 1 to DN 8 [¹⁄₁₀ to ⁵⁄₁₆”]) ABB order no. D173D147U01, 10 m included in shipment, standard Figure 37: Electrical connection transmitter S4 with PROFIBUS PA / FOUNDATION Fieldbus Note •...
  • Page 63: Connection Examples For Peripherals (Incl. Hart)

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Connection examples for peripherals (incl. HART) Current output Switch input internal external internal external Figure 38: Current output active with / without HART protocol (4 ... 20 mA) Figure 40: Switch input for external totalizer reset and external zero return Current output active with / without HART protocol (4 ...
  • Page 64: Pulse Output

    FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Transmitter PROFIBUS PA® / FOUNDATION Fieldbus® Pulse output Active pulse output Pulse output, passive, optocoupler internal external 1 PROFIBUS PA 2 FOUNDATION Fieldbus Figure 42: Digital communication PROFIBUS PA / FOUNDATION Fieldbus The resistance R and condenser C form the bus termination.
  • Page 65 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Connection via M12 plug (for PROFIBUS PA only) Pin assignment (front view showing pin insert and pins) PA− Shielding Figure 44: M12 plug-in connector PROFIBUS PA As an option, the bus can also be connected via an M12 plug instead of the cable gland (see order information for device).
  • Page 66 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Transmitter Dimensions Transmitter housing and suggested installation method 1 Field mount housing with window 3 Mounting holes for pipe mounting set, for 2” pipe mounting; mounting set available on request (order no. 612B091U07) 2 Cable gland M20 x 1.5...
  • Page 67 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L Ordering information Accuracy 0.5% of rate, for FSM4000-SE21 / -SE41 Main order number S4- X FSM4000-S4 External Converter Housing Field housing (cable gland M20 x 1.5) Field housing (cable gland 1/2 in. NPT) Power Supply 100 ...
  • Page 68 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — … Transmitter Additional order number Additional order number FSM4000-S4 External Converter Language of Documentation German English Russian Language package Western Europe / Scandinavia (Languages: FR, ES, DA, IT, NL, PT, SV, FI)
  • Page 69 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — Trademarks FOUNDATION Fieldbus is a registered trademark of FieldComm Group, Austin, Texas, USA. HART is a registered trademark of FieldComm Group, Austin, Texas, USA PROFIBUS, PROFIBUS PA and PROFIBUS DP are registered trademarks of PROFIBUS &...
  • Page 70 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L — Notes...
  • Page 71 FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L...
  • Page 72 We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

Table of Contents