Specifications
Storage temperature
-25 ... 70 °C (-13 ... 158 °F)
Degree of protection acc. to EN 60529
• IP 67
• IP 68 (option)
Pipeline vibration according to EN 60068-2-6
Transmitter
-
In the range of 10...55 Hz, max. deflection 0.15 mm
Flowmeter sensor
-
In the range of 10...55 Hz, max. deflection 0.15 mm
-
In the range of 55...150 Hz, max. acceleration 2 g
Materialload for meters with variable process
connections / wafer type SE21 DN 1 ... DN 100 (1/25 ... 4")
Process
Nominal
connection
diameter
Liner PFA
3 ... 50
Wafer type
(1/10 ... 2")
65 ... 100
(2 1/2 ... 4")
3 ... 40
Weld stubs
(1/10 ... 1 1/2")
50; 80
(2", 3")
65, 100
(2 1/2 ... 4")
3 ... 40
Threaded pipe
connection
(1/10 ... 1 1/2")
50; 80
conforming to
(2", 3")
DIN 11851
65, 100
(2 1/2 ... 4")
3 ... 50
Tri-Clamp
(1/10 ... 2")
conforming to
65 ... 100
DIN 32676
(2 1/2 ... 4")
3 ... 100
Tri-Clamp in acc.
(1/10 ... 4")
with ASME BPE
External threads
3 ... 25
ISO 228
(1/10 ... 1"
1 ... 2
1/8" sanitary
(1/25 ... 1/12")
connectors
120
PS
TS
max
min
[bar]
DN
40
-40 °C
16
(-40 °F)
40
16
-25 °C
(-13 °F)
10
40
16
-25 °C
(-13 °F)
10
16
-25 °C
10
(-13 °F)
10
-25 °C
(-13 °F)
16
-25 °C
(-13 °F)
10
-10 °C
(14 °F)
JIS B2210-10K wafer type
Meter size
Material
DN
1.4404 (316 L),
32 ... 100
1.4435 (316 L),
(1¼ ... 4")
1.4301 (304)
Material load for flange model SE21F
Lining: PFA
PS
[bar]
45
40
35
30
25
TS
max
20
15
10
130 °C
5
(266 °F)
0
-30 -20 -10
0
-22
-4 14 32
Fig. 68:
DIN flange, stainless steel 1.4571 (316 Ti) up to
130 °C
DN 100 (4")
(266 °F)
Liner PFA
PS
[bar]
55
130 °C
50
(266 °F)
45
40
35
30
121 °C
(250 °F)
25
20
130 °C
15
(266 °F)
10
130 °C
5
(266 °F)
0
-30
-10
120 °C
-22
14
(248 °F)
Fig. 69:
ASME flange, stainless steel 1.4571 (316 Ti) up to
DN 100 (4")
Material load for flange model SE21W
Lining: PFA wafer type
PS
[bar]
45
40
35
30
25
20
15
10
5
0
-60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 *) [°C]
-76 -58 -40 -22 -4 14 32 50 68 86 140 122 140158 176194 212 230 248 266 *) [°F]
Fig. 70
*)
For CIP / SIP cleaning, higher temperatures are permitted for limited time periods; refer
to the table titled "Maximum permissible cleaning temperature".
FSM4000
PN
10
PN 40
PN 25
PN 16
PN 10
10 20 30 40 50 60 70 80 90 100 110 120 130 *) [°C]
50 68 86 104 122 140 158 176 194 212 230 248 266 *) [°F]
CL 300
CL 150
10
30
50
70
90
110
50
86
122
158
194
230
TS
PS
[bar]
-40 ... 130 °C
10
(-40 ... 266 °F)
PS
[psi]
652.5
580.0
507.5
435.0
362.5
290.0
217.5
145.0
72.5
0
TS
G00221
PS
[psi]
697.5
725.0
652.5
580.0
507.5
435.0
362.5
290.0
217.5
145.0
72.5
0
130 *) [°C]
TS
266 *) [°F]
G00222
PS
[psi]
652.5
580.0
507.5
PN 40/CL 300
435.0
362.5
PN 25
290.0
217.5
PN 16/CL 150
145.0
PN 10
72.5
0
TS
G00223