Setup
8.3.4
Setup Wizard
The Setup Wizard leads you through the necessary steps for configuring your servo
amplifier. Depending on the selected application, only the active screen pages are
necessary.
8.3.4.1
Basic Setup
Response to Loss of Input Phase: Select Single-Phase or Three-Phase operation.
With three-phase operation you can select either warning "n05" or error "F19" in case of
phase loss. The reaction "F19" disables the output stage, "n05" is just a message.
Name: You can enter a name for the servo amplifier (up to 8 characters). This simplifies
the drive identification in the system.
Set Software Enable on Bootup: Don't select this option for the quick test.
Click NEXT.
114
07/2014
S701x2-S724x2 Instructions Manual
Kollmorgen
For a quick setup / drive
test, select the setup
type "Quick Motor/Drive
Setup".
Start the Wizard.
Basic parameters are
set here.