Expansions
9.2.3.4
Analog Inputs and Outputs
The expansion card "PosI/O-Monitor" adds analog inputs and outputs to the servo ampli-
fier were pre-programmed signals can be assigned to. A listing of these pre-programmed
functions can be found on the screen page "Analog I/O" of the setup software.
9.2.3.4.1
Analog Outputs ANALOG-OUT 1 and 2
You can use terminals X3C/17 (Analog-Out 1) respectively X3C/19 (Analog-Out 2) to deli-
ver analog values converted from internal digital values (e.g. tachometer voltage).
Technical characteristics
—
—
—
—
9.2.3.4.2
Analog Inputs ANALOG-IN 3 and 4
You can use terminals X3C/21-X3C/22 (Analog-In 3) respectively terminals
X3C/24-X3C/25 (Analog-In 4) with several pre-programmed functions.
Technical characteristics
—
—
—
—
—
—
150
Reference ground is Analog-GND (AGND, terminal X3C/18 and X3C/20)
Specification according to EN 61131-2 table 11
Output voltage ±10 V
Resolution: 0.38 mV, 16 Bit, Update rate 250 µs
Differential input voltage max. ± 10 V
Resolution 1.25 mV, 16 bits, scalable
Ground reference AGND, terminal X3C/23
Input resistance 20 kW
Common-mode voltage range for both inputs ± 10 V
Update rate 62.5 µs
07/2014
S700
S700
S701x2-S724x2 Instructions Manual
Kollmorgen