Expansions
9.2.3.1.2
ROD (AquadB) 5V with Hall (X5, X1)
Wiring of a 5V incremental encoder (ROD, AquadB) with Hall sensors as a feedback unit
(primary, ð p.76). For the commutation hall sensors are used and for the resolution an
incremental encoder.
The power supply for the encoder and thermal control in the motor is connected to X1
and evaluated there.
If cable lengths of more than 25m are planned, please consult our customer service.
Frequency limit X5: 1.5 MHz, X1: 350 kHz
Type
AquadB 5V with Hall
144
07/2014
FBTYPE
18
S700
EXTPOS
GEARMODE ENCMODE
-
S701x2-S724x2 Instructions Manual