Appendix D — Serial Configuration Commands
The following table is a list of all the available serial configuration commands (also
called "K commands"). These commands are also listed at the beginning of each appli-
cable chapter. For utility (operational) commands see
ity Serial Commands," on page 11-3.

Table A-8 Complete List of Serial Configuration Commands

Command Title
Host Port Connections
<Kabaud,parity,stop bits,data bits>
Host Protocol
<Kfprotocol>
RS422 Status
<Kbstatus>
<Kyaux port mode,baud,parity,stop bits,data bits,daisy chain sta-
Auxiliary Port
tus,daisy chain ID>
Preamble
<Kdstatus,preamble>
Postamble
<Kestatus,postamble>
LRC
<Kcstatus>
Response Timeout
<KAresponse timeout>
Intercharacter Delay
<KBintercharacter delay>
Multisymbol
<KLnumber of symbols,multisymbol separator>
Trigger Mode
<Kgtrigger mode,filter time>
External Trigger State
<Kjexternal trigger state>
Serial Trigger Character
<Kiserial trigger character>
End of Read Cycle
<Khend of read cycle,read cycle timeout>
Good Decode Reads
<Kmgood decode reads>
Automatic Gain Control
<KD
Scan Speed
<KEscan speed>
Transition Counter
<KHsymbol detect status,transition counter>
Scanner Type
<KPdensity>
<KClaser
Laser Controls
tion>
<Kpstatus,check digit status,check digit output status,large inter-
Code 39
character gap,fixed symbol length status,fixed symbol length,full
ASCII set>
<Kt
EAN-128 status,output format,application record separator status,appli-
Code 128
cation record separator character,application record brackets,applica-
tion record padding>
<Krstatus,check digit status,check digit output,symbol length
Interleaved 2 of 5
1,symbol length 2>
MS-820 Industrial Bar Code Scanner User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 11-1, "Summary of Util-
Format
COMMUNICATIONS
READ CYCLE
gain,AGC sampling,AGC min,AGC max>
on/off,laser framing status,laser on position,laser off posi-
SYMBOLOGIES
code 128 status,fixed symbol length status,symbol length,UCC/
Appendices