Diagnostics by ESP Menu

Diagnostics by ESP Menu

Click this button to bring
up the
Diagnostic
menu.
To change a setting,
double-click
the
setting and use your
cursor to scroll
through the options.
To open nested options,
single-click
the +.

Diagnostics by Serial Command

Command Title
Counts
Hours Since Last Reset
Warning Message Status
Laser High Warning
Laser Low Warning
Present Operating
Temperature
High Temperature Threshold
Low Temperature Threshold
Lifetime Hours
MS-820 Industrial Bar Code Scanner User's Manual
8-2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Format
<K_?> (read only: power-ons, resets)
<K@?> (read only: hours, minutes)
<K"warning message status,laser high status,laser low
status,novram corrupt warning status>
<K;laser high message>
<K:laser low message>
<K%
degrees Celsius>
<K+degrees,message>
<K-degrees,message>
<K$hours10,message>