Low Temperature Threshold
A message can be defined that will display when a user-set Low Temperature
Threshold has been reached. The message repeats once every 30 minutes until the
condition is corrected. This value is a reference to the external ambient temperature in
the environment around the scanner.
Low Temperature Degrees
Usage:
Helps ensure that the scanner is being used within its temperature speci-
fication.
Definition:
The user can set a low temperature value that, whenever the ambient
temperature falls below it, causes a low temperature message to be dis-
played. If Low Temperature Threshold is set to zero, the warning
message will be disabled.
Serial Cmd:
<K–degrees,message>
Default:
1°
Celsius
Options:
0° to 50°, zero disables.
Low Temperature Message
Definition:
The user can enter a message of up to 10-characters that will be dis-
played whenever the ambient temperature falls below the Low Temper-
ature Threshold.
Serial Cmd:
<K–degrees,message>
Default:
LO-TEMP
Options:
Any 1 to 10 character ASCII string except NUL, <, or >.