Operation Command Output

Operation Command Output

Important: This option must be enabled for ESP to operate.
Usage:
Used when brackets are required to delineate certain scanner outputs
such as counters.
Definition:
Controls the output of command brackets.
Serial Cmd:
<K/status>
Default:
Enabled
Options:
0 = Disabled
Disabled
When set to disabled, the start and stop brackets < and > are not sent with responses
to the operational commands such as <T> and <N> and utility commands such as
counters and part number requests do not function.
Enabled
Directs the scanner to bracket non-bar code scanner data such as counters with com-
mand start and stop characters, and echo the command to the host.
MS-820 Industrial Bar Code Scanner User's Manual
6-14
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
1 = Enabled