Engineering and remote access
3.5 Cyclic and acyclic data
Index
Slot
Subslot Data set
0x0008 0
1
0x0009 0
1
0x0010 0
1
0x0010 0
1
0x0011 0
1
0x0012 0
1
0x0013 0
1
0x0014 0
1
0x0015 0
1
0x0016 0
1
0x0020 0
1
0x0040 0
1
0x0041 0
1
0x0042 0
1
0x0043 0
1
92
Type
Buffering parameters
Reading /
from V2.0
writing
Maintenance parame-
Reading /
ters from V2.1
writing
DC-UPS command
Writing
Result of DC-UPS
Reading
command
Battery 1 information
Reading
parameters
Battery 2 information
Reading
parameters
Battery 3 information
Reading
parameters
Battery 4 information
Reading
parameters
Battery 5 information
Reading
parameters
Battery 6 information
Reading
parameters
State information
Reading
Identification value
Reading /
parameters
writing
Web server
Reading /
parameters
writing
OPC UA server
Reading/
writing
NTP client parameters
Reading/
writing
Description
Buffer parameters of the
SITOP UPS1600
Maintenance parameters of the
SITOP UPS1600
Sends special commands to the
SITOP UPS1600
Response to the previously sent
"DC-UPS command"
Information regarding the connected
battery module 1 SITOP UPS1100.
This information is available via the link
"Energy Storage".
Information regarding the connected
battery module 2 SITOP UPS1100.
This information is available via the link
"Energy Storage".
Information regarding the connected
battery module 3 SITOP UPS1100.
This information is available via the link
"Energy Storage".
Information regarding the connected
battery module 4 SITOP UPS1100.
This information is available via the link
"Energy Storage".
Information regarding the connected
battery module 5 SITOP UPS1100.
This information is available via the link
"Energy Storage".
Information regarding the connected
battery module 6 SITOP UPS1100.
This information is available via the link
"Energy Storage".
Status information about
SITOP UPS1600 and the connected
battery modules SITOP UPS1100.
Information about the SITOP UPS1100
battery modules is available via the link
"Energy Storage".
Device identification parameters.
Web server settings of the
SITOP UPS1600.
OPC UA settings of the
SITOP UPS1600.
Setting for connection to NTP servers
Manual, 04.2017, A5E37775406-8-76
Data size
2 bytes
2 bytes
4 bytes
4 bytes
68bytes
(from V2.2)
68bytes
(from V2.2)
68bytes
(from V2.2)
68bytes
(from V2.2)
68bytes
(from V2.2)
68bytes
(from V2.2)
64 bytes
70 bytes
(from V2.1)
80 bytes
108 bytes
(from V2.1)
1 byte
6 bytes (from
V2.1)
4 bytes (from
V2.2)
66 bytes
(from V2.2)
SITOP UPS1600 / UPS1100