Engineering and remote access
3.6 SITOP UPS Manager
6. Configure the Ethernet interface as specified by the network administrator.
7. Select the SITOP UPS1600 in the Tree view.
Loading to the device is not possible while an interface is selected.
8. Select menu command "Module > Download", to load the configuration to the device.
Alternatively, you can start loading using the "Load" button in the toolbar.
Configuring the connection in the SITOP UPS Manager
A basic setting is the configuration of the client (PC/PG) as master or slave. The
consideration of possible application situations can help here:
● The local computer is the only computer at the SITOP UPS1600.
Local computer = master PC
● The local computer is one of several computers and performs the master function.
Local computer = master PC
● The local computer is one of several computers at the SITOP UPS1600 and operates as
slave.
Local computer = slave PC
In the master-slave configuration, the SITOP UPS1600, the master PC and the slave PC are
connected at the same physical Ethernet. Only the master PC communicates directly with
the SITOP UPS1600. The slave PC receives the control signals from the SITOP UPS
Manager of the master PC.
Note
Up to SITOP UPS Manager Version 4.12, the master PC can only manage 1 slave PC. From
version 4.12.5 and higher, up to 8 slaves can be managed.